1 General Information
These instructions serve the repairing of autarkic cooking hobs and cooking hobs in combination with
an oven with 3 or 4 inductions cooking zones respectively of the type E.G.O.. Also includes hobs with
2 induction zones (Domino, Mixed, Mixed gas) and the Frontline appliance series.
Please search for the corresponding alarm
symptom and then go through the alarm remedy measures from top to bottom.
Information concerning the replacement of parts is to be found in the corresponding replacement
instructions or are included with the spare parts.
All work is only to be carried out on the induction modules and the heating elements are only to be
carried out after they have been disconnected.
1.1 Leak current
A leak current of 5mA is normal and is therefore much higher than with other appliances.
1.2 Standby
The Standby power consumption amounts to < 1W (Induction plus user interface in the autonomous,
exception Frontline up to 2W).
The µprocessor for the measuring of the coil temperature is deactivated in standby, i.e. should the
cooking hob be heated up to hot pan being on the zone, no heating display "H“ is displayed when
switched off.
In this condition, the ventilator is also not switched on by external heating.