Operating instructions

11
BURNER RAPID SEMI-RAPID AUXILIARY
(large) (medium) (small)
POSITION MAX MIN MAX MIN MAX MIN
NOMINAL THERMAL
POWER kW 2.9 0.75 1.9 0.45 1.0 0.33
NOMINAL FLOW
RATE m
3
/h 0.276 0.062 0.181 0.043 0.095 0.031
NOZZLE REFERENCE 119 Adjust. 96 Adjust. 70 Adjust.
1/100 mm
NOMINAL THERMAL
POWER kW 2.7 0.75 1.9 0.45 1.0 0.33
NOMINAL FLOW
RATE g/h 195 46.8 137 32.4 72 23.8
NOZZLE REFERENCE 86 40 71 32 50 28
1/100 mm
NATURAL GAS
20 mbar
VALUE =
37.78 MJ/m
3
Ws - 50.7 MJ/ m
3
TYPE OF GAS
LPG GAS
28-30/37 mbar
VALUE =
49.92 MJ/Kg
Important safety requirements
This hob must be installed in accordance with the Gas Safety (Installation and
Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition).
For appliances installed in the Republic of Ireland please refer to NSAI- Domestic
Gas Installation I.S. 813 Current Editions and the ETCI Rules for Electrical
Installations.
Detailed recommendations are contained in the following British Standards Codes
Of Practice: B.S. 6172/ B.S. 5440, Par. 2 and B.S. 6891 Current Editions.
Provision for ventilation
The hob should not be installed in a bed sitting room with a volume of less than 20
m
3
. If it is installed in a room of volume less than 5 m
3
an air vent of effective area of
110 cm
2
is required. If it is installed in a room of volume between 5 m
3
and 10 m
3
an
air vent of effective area of 50 cm
2
is required, while if the volume exceeds 11 m
3
no
air is required.
However, if the room has a door which opens directly to the outside no air vent is
required even if the volume is between 5 m
3
and 11 m
3
.
If there are other fuel burning appliances in the same room, B.S. 5440 Part 2
Current Edition, should be consulted to determine the requisite air vent
requirements.
For appliances installed in the Republic of Ireland please refer to the NSAI-
Domestic Gas Installation I.S. 813 Current Editions Table Four.
Instructions for the Installer