Specific technical data (modified sinusoidal wave)
Model ST 500 ST 800 ST 1200
Item number 97115 97116 97117
Continuous power output 500 W 800 W 1200 W
Peak power output (0.1 sec.) 1000 W 1600 W 2400 W
Dimensions in mm 240 x 180 x 85 308 x 180 x 85 378 x 180 x 85
Weight 1,50 kg 2,17 kg 2,70 kg
Overload protection
550 W ±40 W 880 W ±60 W 1320W ±100 W
Fuse 2x 30 A 3x 30 A 4x 40 A
Specific technical data (pure sinusoidal wave)
Model SW 600 SW 1000 SW 1500 SW 2000
Item number 97120 97121 97122 97123
Continuous power output 600 W 1000 W 1500 W 2000 W
Peak power output (0.1 sec.) 1200 W 2000 W 3000 W 4000 W
Dimensions in mm 378 x 180 x 85 400 x 180 x 85 408 x 180 x 85 530 x 2600 x 85
Weight 2,72 kg 3,30 kg 4,65 kg 6,60 kg
Overload protection
660 W ±40 W 1100 W ±100W 1650 W ±120W 2200 W ±100 W
Fuse 2x 60 A 4x 40 A 6x 30 A 8x 30 A
Power sources suitable for connection
The voltage converter is intended for connection to power sources with 12V direct current. It must have sufficient capa-
city for the consumers connected to the converter.
To calculate the required capacity, divide the consumer load by the voltage.
Example: Consumer load 180 W : 12 V = 15 A
Connecting to power sources with an output voltage other than 12V direct current is prohibited and improper.
Connectible devices
Allowed Not allowed
Devices with a total rated voltage
ST 500 (97115) ‹ 500 W
ST 800 (97116) ‹ 800 W
ST 1200 (97117) ‹ 1200 W
SW 600 (97120) ‹ 600 W
SW 1000 (97121) ‹ 1000 W
SW 1500 (97122) ‹ 1500W
SW 2000 (97123) ‹ 2000 W
(also see “Technical Data”).
Devices with a total rated voltage
ST 500 (97115) > 500 W
ST 800 (97116) > 800 W
ST 1200 (97117) > 1200 W
SW 600 (97120) > 600 W
SW 1000 (97121) > 1000 W
SW 1500 (97122) > 1500 W
SW 2000 (97123) > 2000 W
(also see “Technical Data”).
Note regarding Item 97115, 97116, 97117
The voltage converter provides a modified sinusoidal voltage. To prevent consequential loss, please verify the device to
be powered is suitable (also see “Technology”).