User manual

126 818 33 55-01/8
If the TURBO/FROSTMATIC function is not ended manually, the
appliance electronics switch off the TURBO/FROSTMATIC function of
the freezing mode after approx. 50 hours, and the TURBO/FROSTMATIC
function of the cooling mode after 6 hours. The yellow light goes out.
Important! Once the TURBO/FROSTMATIC function has been switched
on the DESIRED temperature that was set originally cannot be changed.
ALARM OFF button
With the ALARM OFF button, the acoustic warning signal
can be switched off, e.g. the "Open Door" warning when
sorting in or out, the commodities to be frozen.
When there is a temperature warning, if the ALARM OFF button is acti-
vated the temperature display will show the warmest temperature the
frozen food has reached on restoration of the power supply.
Prior to Initial Start–Up
1
Before connecting the appliance to the mains and putting it into oper-
ation for the first time, leave the appliance to stand for 30 minutes if
was transported upright. After transport on its side, the appliance must
be left to stand for 4 hours before putting it into operation. This is nec-
essary to allow the refrigerant to flow back into the compressor. Other-
wise the compressor may be damaged.
0 1. Please clean the appliance interior and all accessories prior to initial
start-up (see section: “Maintenance and Cleaning”).
2. The appliance must be correctly installed in accordance with the chap-
ter "Installation" before it is put into operation for the first time. Care
should be especially taken that the mains voltage and frequency avail-
able correspond with the appliance’s rating plate.
3. Remove the cold accumulation block from the appliance.
4. Only put the cold accumulation block to freeze in the top compartment
after the optimal storage temperature of –18 °C has been reached.
5. After 24 hours place the cold accumulation block in the uppermost
compartment, at the front, above the frozen food.
6. Re-freeze the thawed cold accumulation block in the same way, e. g.
after cleaning the appliance.