operation manual

Deutsch
13
DD
VII
English
TECHNICAL DATA
Dust Extraction
AP 2-200 ELCP
(220-240 V)
Production code 4474 61 03...
... 000001-999999
Rated input P
iec
1000 W
Flow rate max. 3600 l/min
216 m
3
/h
Underpressure max. 21 kPa / 210 mbar
Capacity:
Container
Solid
Liquid
20 l
16 l
13 l
Filter surface 3000 cm²
Outlet maximum Accessory Rating 2600 W
Safety class (Moisture, Dust) IP24
Suction hose diameter 32 mm
Weight according EPTA-Procedure 01/2003 7,5 kg
Noise information
Measured values determined according to EN 60704-1. Typically,
the A-weighted noise levels of the tool are:
Sound pressure level (Uncertainty K=2dB(A)) 72 dB (A)
Sound level / Working sound level (Uncertainty
K=2dB(A))
64 dB (A)
Wear ear protectors!
Vibration information
Total vibration values (vector sum in the three axes) determined
according to ISO 5349.
Vibration emission value a
h
Uncertainty K=
< 1,5 m/s
2
1 m/s
2
WARNING Read all safety warnings and all instruc-
tions.
Failure to follow the warnings and instructions may result in
electric shock, re and/or serious injury.
Save all warnings and instructions for future reference.
SAFETY WARNINGS DUST EXTRACTION
This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they
have been given supervision or instruction
concerning use of the appliance by a person
responsible for their safety. Children should
be supervised to ensure that they do not play
with the appliance.
Fire and explosion hazard!
Never suck up into the machine any inam-
mable or explosive solvents, or liquids like
petrol, oil, alcohol, thinners, or small particles
(such as metal lings or ash) that may be
hotter than 60°C - otherwise there is danger of
explosion or re!
You are not allowed to use the appliance in the
vicinity of inammable gases or substances.
Do not point the nozzle, hose or tube at
people or animals.
SPECIFIED CONDITIONS OF USE
The vacuum cleaners described in this operating manual are
suitable for
sucking up dust and li quids
commercial use, e.g. in hotels, schools, hospitals, factories,
shops, oces and rental businesses.
for separation of dust with an exposure limit of greater than 1
mg/m³, (dust class L).
The following materials should not be picked up by the vacuum
cleaner
hazardous dust
hot materials (burning cigarettes, hot ash, etc.)
ammable, explosive, aggressive liquids (e.g. petrol, solvents,
acids, alkalis, etc.)
ammable, explosive dust (e.g. magnesium or aluminium dust,
etc.)
Any national regulations in this regard must be complied with.
MAINS CONNECTION
Connect only to a single-phase AC current supply and only to the
mains voltage specied on the rating plate. Must only be used from
sockets with earth wire.
Appliances used at many dierent locations including wet room
and open air must be connected via a residual current device (FI,
RCD, PRCD) of 30mA or less.
Extension cables to the mains must at least be protected from
water spray and contain an earth lead.
Only plug-in when machine is switched o.
If the supply cord of this appliance is damaged, it must only be
replaced by a repair shop appointed by the manufacturer, to avoid
hazardous situations.
WORKING INSTRUCTIONS
Do not direct the air into rooms in an uncontrolled manner.
Before liquids are picked up, always remove the lter bag. Ensure
Filter remains tted for wet operating. Check that the oat works
and level indicator hose properly. If foam develops or liquid
emerges, stop work immediately and empty the dirt tank.
Not suitable for sweeping up liquids which form a large foam.
When using the blower function, always use a clean hose.
Stirred-up dust can be hazardous to health. Do not use the blower
function in closed rooms.
Only use the appliance if it is in perfect condition. Never use the
dust extractor without a lter, or if the lter is damaged.
Discard lter elements, lter bags and disposal bags in accordance
with the national regulations.
CONNECTING ELECTRICAL APPLIANCES
The plug socket on the appliance may be used only for the purposes
dened in the usage instructions.
Before plugging an appliance into the appliance socket:
Switch o the vacuum cleaner. Switch o the appliance to be
connected.
GB