User manual

Built in depth of the
appliance
548 mm
Depth with open
door
1022 mm
Ventilation opening
minimum size. Open-
ing placed on the
bottom rear side
560x20 mm
Mains supply cable
length. Cable is
placed in the right
corner of the back
side
1500 mm
Mounting screws 4x25 mm
2.2 Electrical connection
WARNING!
Risk of fire and electric
shock.
All electrical connections should be
made by a qualified electrician.
The appliance must be earthed.
Make sure that the parameters on the
rating plate are compatible with the
electrical ratings of the mains power
supply.
Always use a correctly installed
shockproof socket.
Do not use multi-plug adapters and
extension cables.
Make sure not to cause damage to
the mains plug and to the mains
cable. Should the mains cable need
to be replaced, this must be carried
out by our Authorised Service Centre.
Do not let mains cables touch or
come near the appliance door or the
niche below the appliance, especially
when it operates or the door is hot.
The shock protection of live and
insulated parts must be fastened in
such a way that it cannot be removed
without tools.
Connect the mains plug to the mains
socket only at the end of the
installation. Make sure that there is
access to the mains plug after the
installation.
If the mains socket is loose, do not
connect the mains plug.
Do not pull the mains cable to
disconnect the appliance. Always pull
the mains plug.
Use only correct isolation devices: line
protecting cut-outs, fuses (screw type
fuses removed from the holder), earth
leakage trips and contactors.
The electrical installation must have
an isolation device which lets you
disconnect the appliance from the
mains at all poles. The isolation
device must have a contact opening
width of minimum 3 mm.
This appliance is supplied with a main
plug and a main cable.
Cable types applicable for installation
or replacement for Europe:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F,
H05 V2V2-F (T90), H05 BB-F
For the section of the cable refer to the
total power on the rating plate. You can
also refer to the table:
Total power (W) Section of the ca-
ble (mm²)
maximum 1380 3 x 0.75
maximum 2300 3 x 1
maximum 3680 3 x 1.5
The earth cord (green / yellow cable)
must be 2 cm longer than phase and
neutral cables (blue and brown cables).
2.3 Use
WARNING!
Risk of injury, burns and
electric shock or explosion.
This appliance is for household use
only.
Do not change the specification of
this appliance.
Make sure that the ventilation
openings are not blocked.
Do not let the appliance stay
unattended during operation.
Deactivate the appliance after each
use.
ENGLISH
5