HI 8820 CHDI 8820 Dunstabzugshaube Afzuigkap Hotte Cooker Hood Montage- und Gebrauchsanweisung Installatie- en gebruiksaanwijzing Notice dutilisation et dinstallation Operating and Installation Instructions
Contents Safety warnings For the User For the Installer 62 62 62 Description of the Appliance Extraction Recirculation 64 64 64 Control Panel Control device for grease and charcoal filters Grease filter LED (D) Charcoal filter LED (E) Resetting the saturation indicator 65 66 66 66 66 Maintenance and care Cleaning the hood Metal grease filter Removing the metal grease filter Charcoal filter Changing the light bulb 67 67 67 67 68 69 What to do if 70 Special accessories 70 Technical assistance serv
Safety warnings For the User The cooker hood is designed to extract unpleasant odours from the kitchen, it will not extract steam. Always cover lighted elements, to prevent excess heat from damaging the appliance. In the case of oil, gas and coal fired cookers it is essential to avoid open flames. Also, when frying, keep the deep frying pan on the cooker top/cooker under careful control. The hot oil in the frying pan might ignite due to overheating.
The national Standard on fuel-burning systems specifies a maximum depression of 0.04 mbar in such rooms. The air outlet must not be connected to chimney flues or combustion gas ducts. The air outlet must under no circumstances be connected to ventilation ducts for rooms in which fuel-burning appliances are installed. The air outlet installation must comply with the regulations laid down by the relevant authorities.
Description of the Appliance The hood is supplied as an extractor unit and can also be used with a filtering function by fitting one charcoal filter. You will need an original AEG charcoal filter for this function (Available from your local AEG Service Force Centre). Only for CHDI 8820: The cooker hood is supplied ready for use as a recirculation hood and may be used for extraction by removing the charcoal filter which has been fitted inside the cooker hood.
Control Panel Best results are obtained by using a low speed for normal conditions and a high speed when odours are more concentrated. Turn the hood on a few minutes before you start cooking, you will then get an under pressure in the kitchen. The hood should be left on after cooking for about 15 minutes or until all the odours have disappeared. The control switches are located on the units front panel. 1 2 3 a b 4 5 6 Fig.
Control device for grease and charcoal filters This hood is fitted with a device that signals when it is necessary to clean the grease filter or the charcoal filter (if the hood is used in the recirculation version with a charcoal filter). On delivery, the hood is not supplied with a charcoal filter, so the saturation indicator will be disabled.
Maintenance and care The hood must always be disconnected from the electricity supply before beginning any maintenance work. Cleaning the hood Clean the outside of the hood using a damp cloth and a mild detergent. Never use corrosive, abrasive or flammable cleaning products. Never insert pointed objects in the motors protective grid. Wash the outside surfaces using a delicate detergent solution. Never use caustic detergents or abrasive brushes or powders.
Charcoal filter The charcoal filter should only be used if you want to use the hood in the recirculation function. To do this you will need an original AEG charcoal filter (available from your local Service Force Centre). Cleaning/replacing the charcoal filter Unlike other charcoal filters, the LONGLIFE charcoal filter can be cleaned and reactivated. At normal use the filter should be cleaned every second month (when using the hood 2,5 hours per day, in avarage).
Warning Failure to observe the instructions on cleaning the unit and changing the filters will cause a fire hazard. You are therefore strongly recommended to follow these instructions. The manufacturer declines all responsibility for any damage to the motor or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations. Changing the light bulb Disconnect the cooker hood from the mains supply. Remove the lamp cover, use a screw driver as a lever.
What to do if If your appliance fails to work properly please carry out the following checks. Symptom Solution The cooker hood will not start... Check that: The hood is connected to the electricity supply. Check that a fan speed has been selected The cooker hood is not working effectively.. Check that: The fan speed is set high enough for the task. The grease filters are clean. The kitchen is adequately vented to allow the entry of fresh air.
Technical assistance service (not for UK) You are welcome to telephone our technical assistance service (see list of technical assistance centres) whenever you need information or in the unlikely event of a fault. For service in Australia call 1300 650 020. When calling, please be ready to specify: 1. The model code number 2. The serial number (E-Nr.) 3. The manufacturing number (F-Nr.) This information is shown on the registration plate inside the unit behind the grease filter.
Technical Specifications Dimensions: Height x Width x Depth (in cm) Maximum absorbed power: Motor absorption: Lighting: Length of the cable: Electrical connection: 81,5-110 x 120 x 70 255 W 1 x 175 W 4 x20 W 150 cm 220-240 V Mounting accessories included 1 1 6 6 14 4 14 14 2 14 72 Reduction flange Ø 150-125 Deflector Wood-screws 6 x 70 mm Wall plugs Ø 10 mm Nuts Metal-screw 3 x 9 mm (2 upper chimney fixing + 2 for chimney brackets) Metal-screw 4 x 8 mm (4 for additional structure fixing + 10 to fix hood
Electrical connection (not for UK) Safety warnings for the electrician Before connecting the appliance to the power supply, check that the voltage indicated on the rating plate corresponds to the mains power supply available. Appliances fitted with a plug can be connected to any standard power socket within easy access. Should it be necessary to provide a fixed connection, the hood must only be installed by an electrician authorised by the local electricity board.
Installation - Fig. 7-8-9-10 Assembling the deflector (3 parts only for filter version): The three parts should be fixed with 2 screws, the deflector extension is adjustable and should correspond to the width of the chimney flue support, to which it is then fixed. Fig. 7. Expansion plugs are provided to secure the hood to most types of ceilings. However, a qualified technician must verify suitability of the materials in accordance with the type of ceiling.
3 4 273 4 4 4 244 4 4 6 6 273 190 7 14,5 5 6 214 9 7 7 8 8 7 7 2a 2a 2b 2b 12 10 11 10 10 10 11 Fig.
For extractor versions (13A), connect the other end of the exhaust pipe to the flue. For filter versions (13F), fit deflector F to the support and secure it to the bracket supplied using 4 screws, then connect the exhaust pipe to the connection ring located on the deflector. Fit the nuts with fixing hooks (14) supplied inside the top and bottom sections of the flues at the rectangular slots. A total of 14 nuts must be fitted.
14 F 15b 13F 15b 15b 15b 16 15b 15a 15b 15b 16 13A 15b 15b Fig.
18 18 18 18 18 18 18 18 18 18 M 17 19 19 X 20 20 Fig.
79
From the Electrolux Group. The world´s No.1 choice. The Electrolux Group is the world´s largest producer of powered appliances for kitchen, cleaning and outdoor use. More than 55 million Electrolux Group products (such as refrigerators, cookers, washing machines,vacuum cleaners, chain saws and lawn mowers) are sold each year to a value of approx. USD 14 billion in more than 150 countries around the world. AEG Hausgeräte GmbH Postfach 1036 D-90327 Nürnberg http://www.aeg.hausgeraete.de http://www.aeg.co.