Operating Instructions and Installation Instructions

26
Installation - for qualied contractors
11. Commissioning
WARNING Electrocution
Commissioning may only be carried out by a qual-
ied contractor in accordance with safety regula-
tions.
11.1 Initial start-up
D0000041981
» Open and close all connected draw-off valves sever-
al times, until all air has been vented from the pipe-
work and the appliance.
» Carry out a tightness check.
» Enable the safety pressure limiter by rmly pressing
the reset button (the appliance is delivered with the
safety pressure limiter disabled).
» Plug the temperature selector cable plug into the
PCB.
» Fit the appliance cover, ensuring it clicks into place.
Check that the appliance cover is seated correctly.
» Switch the mains power ON.
» Check the function of the appliance.
Appliance handover
» Explain the appliance function to users and familiar-
ise them with its operation.
» Make users aware of potential dangers, especially
the risk of scalding.
» Hand over these instructions.
11.2 Recommissioning
Vent the appliance and the cold water inlet line (see chap-
ter “Settings”).
See chapter “Initial start-up”.
12. Shutting down
» Isolate all poles of the appliance from the power
supply.
» Drain the appliance (see chapter “Maintenance”).
13. Troubleshooting
WARNING Electrocution
To test the appliance, it must be supplied with power.
Possible indications of diagnostic trafc light
(LED)
Red Illuminates in the event of a fault
Yellow Illuminates during heating mode
Green Flashing: Appliance is supplied with mains
power
1
D0000041794
1 Diagnostic trafc light