Installation – for qualied contractors
18 Nm
26_02_02_0765
24
1
26_02_02_1006
9.4 Wireless remote control installation
The transmitter can be tted to the wall with the wall
retainer. The wall retainer can be secured to the wall with
the adhesive tape supplied or with a suitable countersunk
screw 3 mm (or smaller).
Standard delivery - wireless remote control
OFF
3s
1 2 3
D0000037820
1 Transmitter incl. battery
2 Wall retainer
3 Adhesive pad
10. Commissioning
10.1 Appliance
Commissioning must only be carried out by a contractor.
26_02_02_0888
1
2
3
4
5
» Fill and vent the appliance. Please note - boil-dry risk
(1).
Open and close all connected taps several times,
until all air has been vented from the pipework and
the appliance.
» Activate the safety pressure switch (2) at ow
pressure by pressing the reset button. The appliance
is supplied with the safety pressure limiter in the
triggered state.
» Push the temperature selector cable plug onto the
PCB (3).
» Fit the appliance cover.
For this, hook the appliance cover into the top and
pivot it onto the back panel. The cover must click
audibly into place (4).
Check the rm seat of the appliance cover.
» Switch the mains power ON (5).
» Check the appliance function.
10.2 Wireless remote control FBM Comfort
The wireless remote control is registered at the appliance
in the factory. If there is no data communication during
commissioning, carry out a self-learning process as
follows: Use the ECO key to select the comfort function
Wireless remote control (rc)”, press memory key 1 on the
appliance (this enables the self-learning phase; the bar
graph indication on the display runs), then press any key
on the wireless remote control.
11. Handover
Explain the functions to the user. Draw special attention
to the safety information. Hand these instructions to the
user.