13.3 Details on energy consumption
Product data complies with EU regulations relating to the Directive on the ecodesign of energy related products (ErP).
DDLE ÖKO TD 18 DDLE ÖKO TD 18/21/24 DDLE ÖKO TD 27
222396 222398 222399
Manufacturer AEG Haustechnik AEG Haustechnik AEG Haustechnik
Load profile S S S
Energy efficiency class A A A
Annual power consumption kWh 477 477 481
Energy conversion efficiency % 39 39 39
Default temperature setting °C 60 60 60
Sound power level dB(A) 15 15 15
Special information on measuring efficiency None Data at Pmax. Measured with flow restric-
tion on 9 Ltr/min
13.4 Wireless remote control
Model FBM Comfort
Dimensions (H/W/D)
excl. wall retainer
50/50/17 mm
Weight excluding wall retainer 30 g
Radio frequency 868.3 MHz
Range inside building
incl. one separating ceiling
25 m approx.
Temperature setting range 30 °C - 60 °C
Protection level to EN 60529 Shower = IP X5
Bath = IP X7
Battery type CR 2032
13.5 Appliance
DDLE ÖKO TD 18 DDLE ÖKO TD 18/21/24 DDLE ÖKO TD 27
222396 222398 222399
Electrical details
Rated voltage V 380 400 415 380 400 415 380 400
Rated output kW 16.2 18 19.4 16.2/19/21.7 18/21/24 19.4/22.6/25.8 24 27
Rated current A 24.7 26 27 27.6/29.5/33.3 29/31/35 30.1/32.2/36.3 37.1 39
Fuse A 25 25 32 32/32/35 32/32/35 32/32/40 40 40
Phases 3/PE 3/PE 3/PE
Frequency Hz 50/60 50/60 50/- 50/60 50/60 50/- 50/60 50/60
Max. mains impedance at 50Hz Ω 0.379 0.360 0.347 0.284 0.270 0.260 0.254 0.241
Specific resistance ρ
15
≥ (at ϑcold ≤25 °C) Ω cm 900 900 1000 900 900 1000 900 900
Specific conductivity σ
15
≤ (at ϑcold ≤25 °C) μS/cm 1111 1111 1000 1111 1111 1000 1111 1111
Specific resistance ρ
15
≥ (at ϑcold ≤45 °C) Ω cm 1200 1200 1300 1200 1200 1300 1200 1200
Specific conductivity σ
15
≤ (at ϑcold ≤45 °C) μS/cm 830 830 770 830 830 770 830 830
Connections
Water connection G 1/2 A G 1/2 A G 1/2 A
Application limits
Max. permissible pressure MPa 1 1 1
Max. inlet temperature for reheating °C 45 45 45
Values
Max. permissible inlet temperature °C 65 65 65
ON l/min >2.5 >2.5 >2.5
Flow rate for pressure drop l/min 5.2 5.2/6.0/6.9 7.7
Pressure drop at flow rate MPa 0.08 0.08/0.1/0.13 0.16
DHW delivery l/min 9.9 9.9/11.6/13.2 14.9
Δϑ at DHW delivery K 26 26 26
Hydraulic data
Rated capacity l 0.4 0.4 0.4
Versions
Connected load options - X -
Temperature adjustment °C 30-60 30-60 30-60
Insulation block Plastic Plastic Plastic
Heating system heat generator Bare wire Bare wire Bare wire
Cap and back panel Plastic Plastic Plastic
Colour white white white