15.8 
DDLT PinControl 13 DDLT PinControl 18 DDLT PinControl 21 DDLT PinControl 24
222384 222385 222386 222387

Rated voltage V 400 400 400 400
Rated output 400 V stage I min. kW 4,6 6,3 7,4 8,3
Rated output 400 V stage I max. kW 10,6 14,3 16,8 19,0
Rated output 400 V stage II min. kW 6,8 9,2 10,8 12,2
Rated output 400 V stage II max. kW 13,3 18,0 21,1 23,8
Rated output kW 13,5 18 21 24
Rated current A 19,5 26 31 35
Fuses A 20 25 32 35
Phases 3/PE 3/PE 3/PE 3/PE
Frequency Hz 50 50 50 50
Specific resistance ρ
15
≥ (at ϑcold ≤25 °C) Ω cm 900 900 900 900
Specific conductivity σ
15
≤ (at ϑcold ≤25 °C) μS/cm 1111 1111 1111 1111
Versions
IP-Rating IP25 IP25 IP25 IP25
Protection class 1 1 1 1
Insulation block Plastic Plastic Plastic Plastic
Heating system heat generator Bare wire Bare wire Bare wire Bare wire
Connections
Water connection G 1/2 A G 1/2 A G 1/2 A G 1/2 A

Max. permissible pressure MPa 1 1 1 1

Max. permissible inlet temperature °C 25 25 25 25
ON stage I l/min 2,4 3,0 3,5 4,1
ON stage II l/min 3,9 4,9 5,6 6,3
Pressure drop at flow rate MPa 0,09 0,11 0,13 0,15
Flow rate for pressure drop l/min 3,9 4,5 5,6 6,3
Flow rate limit at l/min 4,7 5,9 7,0 7,8
DHW delivery l/min 7,0 9,4 11,1 12,5
Δϑ at DHW delivery K 26 26 26 26

Rated capacity l 0,4 0,4 0,4 0,4
Dimensions
Height mm 485 485 485 485
Width mm 226 226 226 226
Depth mm 93 93 93 93
Weights
Weight kg 3,6 3,6 3,6 3,6
-
After use,
WARRANTY
ENVIRONMENT AND RECYCLING