Operating Instructions and Installation Instructions

18
Operation - for users and contractors
2.3 Test symbols
See type plate on the appliance.
Country-specic approvals and certications:
Germany
A general test certicate as verication of suitability re-
garding noise emissions has been issued for this appli-
ance, based on the State Building Regulations [Germany].
AEG
HOL
DIN 4109
PA-IX 6817/I
3. 
The hydraulically controlled instantaneous water heater
heats water as it ows through the appliance. When a tap
is opened, the heating output starts automatically as soon
as the start-up volume is exceeded (see chapter "Speci-
cation / Data table"). The water volume and temperature
can be adjusted at the tap.
You can choose between 2 output stages. In addition, 2
output stages are hydraulically controlled in relation to the
ow rate.
The ow rate controller compensates for pressure uc-
tuations, thereby ensuring largely stable temperatures.
The controller limits the throughput, thereby ensuring an
adequate increase in the DHW temperature at all times.

The bare wire heating system has a pressure-tested plas-
tic casing. The heating system is suitable for hard and soft
water areas and is largely insusceptible to scale build-up.
This system ensures rapid and efcient DHW availability.
4. Settings
26_02_02_0783
2 1
1 Partial load
At low throughput 1/3 of the heating output is activat-
ed; at higher throughput 2/3 of the available heating
output is enabled. This setting is suitable for hand
washing at a basin, for example.
2 Full load
At a low throughput, 50 % of the heating output is ap-
plied; at a higher throughput the full heating output is
activated. This setting is suitable for washing dishes,
for example.
» Click the output selector into the required position.


» Set the output selector to full power.
4.1 
Note





» 
Low draw-off rate = high outlet temperature
High draw-off rate = low outlet temperature

 
Partial load Washbasin
Full load Bath, shower, sink
» Add cold water if the temperature is too high when
the tap is fully open.

 
Full load All
» Turn the tap lever to the highest temperature.
» Fully open the tap.
» Increase the outlet temperature by closing the tap
slowly.
» Reduce the outlet temperature by adding cold water
or opening the tap further, if possible.

!

-



» -

» 


» 