Equipment Operation of fume extractor hood important! The appliance may only be switched on when fully installed, 1. e. with applied pipe section and outlet grit {return air operation} or with connected exhaust air pipe system {exhaust air operation! Appliance description (Fig. 1) © The required operating mode (motor running andiron lighting) can be ore selected on the control panel, The appliance is then switched on and off by opening and closing the door.
Technical data Fan outputs to DIN 44971 “Min DEALERSHIP | exhaust air 140 DEMIGOD | returnable 100 Continuously "Max” intensive variable 300 480 260 340 *Exhaust air with 120 mm dia.
Electrical installation Electrical connection {appliances with connected load below 3000 waits) Warning! Al appliances with a 3 core deaf must be earthed. Voltage and current Please ensure that the voltage and current indicated on the rating plate agree with the voltage of your electricity supply. 220/240 volts — (i 8. 220240 Va ¢} Electrical connection Please note! (For users in the UK.
Electrical installation Arrangement of the protective contact plug socket directly above the fume extractor hood or above the overhead cabinet confers two advantages: 1. The plug socket is not visible. 2. You can easily DE-energize the appliance where necessary by unplugging it. For the necessary fixed connection, the fume extractor hood should be connected only by an electrical installer registered with the competent electricity supply company.
installation options installation in furniture surround (DEI 60 PL 2) installation between two cabinets (DEA 60 PL2) Installation by wall mounting at end of wall cabinet run (DEA 60 PL 2} Exhaust air operating mode Preparation as exhaust air appliance 1 the Kitchen fume is run out into the open air through the external wall, you need a telescopic wall box (special accessory, Fig. 4). Wall box with supply and exhaust alr duct, Dimensions and position of air outlet openings: {Fig. 5) DEIST PL 2 (Fig.
Preparation of furniture surround for exhaust air operation The design of appliance DEI 60 PL2 enables the exhaust air hose guide in the appliance rebound area to be run backwards or to one side. After removal of the caver panel {Fig.
installation 9. The fume extractor hood is now to be completed depending on operating mode: Exhaust air operation: Couple exhaust air stern with exhaust air connection-piece on appliance side. Refit cover panel (Fig. 7). Return air operation: Fit pipe connection through furniture ceiling on exhaust alr connection-piece on appliance side. Place outlet grille on pipe connection and screw lag ether with furniture selling (35 x 85) (Fig.
Installation by wall mountain at end of wall cabinet run (D%A 60PL 2) . Mark out fop edge of cabinet {(extension of top edge of neighboring cabinet), 2. Apply riling template — arrow, top edge of cabins — and mark out and drill {6 mm dia) two mounting holes each for wall mounting angle and wall end panel. Wall mounting angle is always to be fitted on opposite side of wall cabinet, 3. Apply wall mounting angle {see illustration on page 30/} to wall plug at slot center and screw together.
Installation Carcass depth "Y" Adjustment dimension X" corresponding (o furniture body depth “Y 5 Top sedge of cabinetmaking & Aligning measure “X” Adjusting screw, " wall joining plate ¥ 320133073407 350 Y 3007310
Installation Fitting the furniture front panel on the fume protection panel installation — DEi ~ in furniture surround . Determine dimension between cabinet effing {bottom edge) and door top edge {neighborliness cabinet} and mark in supplied template (dimension This dimension then corresponds 16 top edge of the furniture door. Place template centrally on rear of furniture front pane {Fig. 22) and mark out mounting holes.
For the user Important instructions 1t must be ensured that open flame hobs are always covered so that the filter mats are not damaged by excessive heat liberation. During deep-frying over a cooker, the appliance used for deep-frying must also be continuously supervised during operation, The olf contained in the deep-frying appliance may spontaneously ignite through overheating. If contaminated oil is used, spontaneous ignition may censure even more readily.
Function description 2. Blower run-on By additionally pressing the bunion {8}, with pres elected switch and bunion smelting "On” for continuous blower operation and lighting, blower run-on can be switched on for a limited time e.g. at the end of cooking to eliminate residual odors from the kitchen. This run-on function only operates when the mute protection panel is closed. The pilot lamp (8) now shows. After 15 minutes, blower and lighting are autocratically switched off.
Maintenance and care Inserting/changing the active carbon filter in return air mode The active carbon filter must be changed not tater than after 12 months. The active carbon fitter cannot be washed or regenerated, Good deodorization is conditional upon a functional active carbon volume matched 1o the air ducting of your fume extractor hood, This high-grade filter carbon will then retain an effective deodorizing effect for around 1 year under conditions of average household use.
Maintenance and care Light bulb change Before changing light bulbs, place light switch (Fig. 25} on "0". 1. Unscrew screws of lamp cover (Fig. 27) and remove damp cover. 2. Unscrew defective candle lamp and replace with new one. important; Use 60 W candle lamps, E 14 socket! You can change the light burbs yourself! Cleaning At least once per yea, you should clean internal surfaces of your appliance free of grease deposits to ensure that its full reliability is retained.
Faults In case of any inquiries and faults, please cal our telesales service (see fist of service crescent. When calling, please state the following: 1. The mods! designation 2. The E-No: 3. The F-No. You will find these data on the rating plate after opening the grease filter grille on the RH inside of the fume extractor hood. The manufacturer reserves the right to make alterations in design and color in the interests of technical development without price notice.