Operating instructions

Table Of Contents
Protect PV.600/800 OD Series - Operating Instructions
8000041160 BAL Page 97 of 100
I
mplementation
i
Secure cabinets against tipping over before lifting them from
t
he ground.
1. Remove the roof and install the transport eyelets/supporting
brackets.
2. Unscrew the screw connections from the ground.
3. Lift off and remove the equipment using lifting gear.
11.3 Packaging
The unit must be packaged for transport if it is to be moved to a
different location.
The equipment must be fastened to a transport pallet with 4 bolts
to ensure better stability. Pack it airtight in plastic film along with
desiccant to protect it from moisture.
Depending on the type of transport, further safety and packaging
measures may need to be adopted.
11.4 Disposal
11.4.1 Statutory Provisions
Equipment at the end of its life is electrical scrap.
In commercial contexts, the manufacturer is responsible for the
disposal of electrical scrap unless otherwise agreed. Electrical
scrap must always be disposed of by an expert.
Electrical and electronic scrap must only be disposed of in
compliance with local legislation and regulations (German)
ElektroG, 2002/96/EG (WEEE), Basel Convention.
Electronic scrap consists of valuable materials which can be re-
claimed as secondary raw materials, but it also contains environ-
mentally harmful substances.
Commercial disposal companies have information on the best way
to recycle material (e.g. in the form of a recycling handbook).
For example, it is possible to recycle:
PCBs and circuit boards
Electronic components, EPROMs, ICs and relays
Chips, processors, hard disks and drives
Batteries
11.4.2 Chemical System Components
AEG PS complies with the restrictions on the use of hazardous
substances in electrical and electronic units according to (German)
ElektroG Section 5 (2002/95/EC).