INSTALLATION
18
12e
8
CONNECTION IN DUCTING VERSION
When installing the hood in ducting version, a rigid
or a flexible pipe with the diameter corresponding
to the flange diameter is used in order to connect
the hood to the air outlet piping.
•Fix the pipewithan adequate quantityof pipe
clamps (not supplied).
•Removepossiblecharcoalfilters.
CONNECTION IN RECYCLING VERSION
•Cutaholeø125mminanyshelfthatmaybeposi-
tioned over the hood.
•Inserttheflange10a on the hood body outlet.
•Connecttheflangetotheoutletontheshelfover
the hood using a flexible or rigid pipe ø120 mm.
•Fixthepipeinpositionusingsufficientpipeclamps
(not supplied).
•Fixthedirectionalgrille8 on the recirculation air
outlet using the 2 screws 12e (2,9 x 12,7) provid-
ed.
•Ensure that the activated charcoal filters have
been inserted.
ELECTRICAL CONNECTION
•Connectthehoodtothemainsthroughatwo-poleswitchhavingacontactgapofatleast3
mm.