13.7 Connecting the terminal
board
The appliance has a six-pole terminal
board. The jumpers (bridges) are set for
operation on a 400 V three-phase with a
neutral wire.
L 1 – 2 – 3 = phase cables
N 4 = neutral cable
= earth cable
If the mains voltage is different,
rearrange the jumpers on the terminal
board (refer to the connection diagram
below). Connect the ground cable to the
terminal. After you connect the supply
cable to the terminal board, attach it with
a junction clamp.
35 66187 39
230V ~
230V ~
1 2 3
5 4
2N ~
230V ~
1 2 3
5 4
3N ~
230V ~
1 2 3
5 4
14. ENERGY EFFICIENCY
14.1 Product Fiche and information according to EU 65-66/2014
Supplier's name AEG
Model identification EES33101ZM
Energy Efficiency Index 95.3
Energy efficiency class A
Energy consumption with a standard load, conven-
tional mode
0.95 kWh/cycle
Energy consumption with a standard load, fan-forced
mode
0.81 kWh/cycle
Number of cavities 1
Heat source Electricity
Volume 72 l
Type of oven Built-Under Oven
Mass 29 kg
EN 60350-1 - Household electric cooking
appliances - Part 1: Ranges, ovens, steam
ovens and grills - Methods for measuring
performance.
14.2 Energy saving
The oven contains features
which help you save energy
during everyday cooking.
General hints
Make sure that the oven door is closed
properly when the oven operates. Do not
open the door too often during cooking.
Keep the door gasket clean and make
sure it is well fixed in its position.
Use metal dishes to improve energy
saving.
When possible, do not preheat the oven
before you put the food inside.
www.aeg.com26