snow with FORCE HEAT, before OFF TEMP is changed.
The heat does not shut o after ice/snow melting
o Afterrun time is too long – reduce AFTERRUN time and activate
RESTART in the menu.
o Moisture detection in the GROUND SENSOR/GUTTER SENSOR
is turned o – set MOIST CTRL to ON in the menu.
If the ALARM button flashes red, one of the following errors has oc-
curred. This can be displayed under the menu: ALARM.
”TEMP SENSOR 1” - Temperature sensor in ground or roof
sensor 1 defective.
”TEMP SENSOR 2” - Temperature sensor in ground or roof
sensor 1 defective.
”OUTDOOR SENSOR” - Outdoor sensor defective.
”SENSOR HEATER” - Short circuit of heating element in
ground or roof sensor.