FRTD 903 TC FRTD 903 TC • Deutsch • English Developed by OJ Electronics A/S - www.ojelectronics.
FRTD 903 TC Fig. 1 BR1017A01 ILLUSTRATIONS Pages.................................................................................... 3 INSTRUCTIONS Deutsch ................................................................................ 7 BR1017A01 English ................................................................................ 12 BR1017A02 BR1017A02 Fig.
FRTD 903 TC Fig. 3 Fig. 5 BR1017A03A FRTD 903 TC 1.5m BR1017A05A L N 5 6 BR1017A03a BR1017A05a 1 2 3 4 Fig. 6 Fig.
FRTD 903 TC Fig. 7 FRTD 903 TC 1 Anleitung Deutsch 2 3 BR1017A14 4 4 Fig. 8 1 BR1017A07 OFF 2 Manual Menu Auto Fig. 9 °Celsius °Fahrenheit Ohm (Ω) -10°C 14°F 55076Ω 0°C 32°F 34603Ω 10°C 50°F 22284Ω 20°C 68°F 14675Ω 30°C 86°F 9860Ω © 2016 OJ Electronics A/S - EHT Haustechnik GMBH BR1017A17 NTC 12kΩ @ 25°Celsius 6 Der Thermostat ist ein elektronischer PBM/PI-Thermostat zur Temperaturregelung mittels extern angebrachtem oder im Thermostat eingebauten NTC-Fühler.
FRTD 903 TC Deutsch Um einem Kontakt der Klemmenleiste des Bodenfühlers mit losen Drähten der vorhandenen Installation vorzubeugen, müssen diese mit Kabelbindern festgemacht werden. Es empfiehlt sich, Kabel und Fühler in einem im Boden eingelassenen, nicht leitenden Installationsrohr anzubringen. Mit verschlossenem Rohrende sollte das Rohr so hoch wie möglich in der Estrichschicht eingebettet sein. Alternativ kann der Fühler direkt im Boden eingebettet werden.
FRTD 903 TC Deutsch Programmierung Siehe Benutzerhandbuch: http://www.aeg-haustechnik.de/fachpartner/produkte/gaw/fussbodenheizungen/ ABB. 9 - FEHLERSUCHE UND -BEHEBUNG Bei unterbrochenem oder kurzgeschlossenem Fühler wird die Heizanlage abgeschaltet. Der Fühler lässt sich mit der Widerstandstabelle abgleichen. Fehlercodes E0: Interner Fehler. Der Thermostat muss ausgetauscht werden. E1: Interner Fühler defekt oder kurzgeschlossen. Thermostat austauschen, oder nur den Bodenfühler verwenden.
FRTD 903 TC FRTD 903 TC Instruction English FIG. 1 - CONTENT • Thermostat • Sensor The thermostat is an electronic PWM/PI thermostat for temperature control by means of an NTC sensor located either externally or internally within the thermostat. The thermostat is for flush mounting in a wall socket. A baseplate for wall mounting is also available. This thermostat can be used as a controller for electric room heating pursuant to EN50559.
FRTD 903 TC English FIG. 6 + 7 - MOUNTING THE THERMOSTAT 1. Mount the thermostat in the wall socket. 2. Fit the frame and carefully press the cover onto the thermostat - starting with the upper part of the cover, then the lower part of the cover. Ensure that both the power slide button on the cover and the power switch pin in the thermostat are down. 3. Click the cover into place by applying light, even pressure. Warning! Do not apply pressure to the corners of the display cover or to the display itself.
FRTD 903 TC English TECHNICAL DATA Voltage ........................................................................ 100-240 VAC Max. pre-fuse..............................................................................16 A Built-in circuit breaker................................................... 2-pole, 16 A Output relay............................................ make contact - SPST - NO Output............................................................................... max. 16 A Terminal wire size.
18 © 2016 OJ Electronics A/S - EHT Haustechnik GMBH © 2016 OJ Electronics A/S - EHT Haustechnik GMBH 19
entrale Vertriebszentrale International International Australia Australia Austria Austria Holzminden STIEBEL ELTRON Ges.m.b.H. Eferdinger Str. 73 4600 Wels Tel. 07242 47367-0 Fax 07242 47367-42 37603 Holzminden Belgium Belgium chnik GmbH EHT Haustechnik GmbH AEG aße 10 g echnik.de echnik.de -250 -444 Markenvertrieb AEG Gutenstetter Straße 10 90449 Nürnberg info@eht-haustechnik.de www.aeg-haustechnik.de Tel. 0911 9656-250 Fax 0911 9656-444 stzentrale Kundendienstzentrale tr.