Specifications

106
Protocol Parameters Jetter Section 12-3
12.3 Protocol Parameters Jetter
The following parameters are set for the protocol PASE/PASE-E:
Baud rate: 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 357000,
500000 Baud
Parity: none, even, odd
Data bits: 5, 6, 7, 8
Stop bits: 1, 1.5, 2
Handshake: no handshake, hardware, software
The following parameters are set for the protocol PCOM5 :
Baud rate: 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 357000,
500000 Baud
Parity: none, even, odd
Data bits: 5, 6, 7, 8
Stop bits: 1, 1.5, 2
Handshake: no handshake, hardware, software
The default parameters of the programming system are printed in bold.
12.3.1 Parameter Maximum Waiting Time for Response
This timer indicates the length of time that the operating terminal will wait for the
response from the PLC.
Permitted values are in the range of 0 ms to 65535 ms.
The default value is 500 ms.
12.3.2 Parameter Delay Until Connection Setup
Specifies the period of time that the terminal allows to elapse after an unsuccessful
attempt to establish the communication and before making another attempt.
Permitted values are in the range of 500 ms to 65535 ms.
The default value is 1000 ms.
12.3.3 Parameter Jetter CPU-Type
Depending on the configuration of the PLC a CPU-type must be selected for the
protocol.
The following CPU-types can be selected:
- PASE-Micro
- PASE-E
- Delta
- Nano
12.3.4 Parameter Protocol-Type
As protocol-type the entries PASE-E or PCOM5 can be selected.