User manual

from liquid gas to natural gas G20
20 mbar, undo the bypass screw
approximately 1/4 of a turn.
WARNING!
Make sure the flame does
not go out when you quickly
turn the knob from the
maximum position to the
minimum position.
8.5 Electrical connection
Make sure that the rated voltage and
type of power on the rating plate
agree with the voltage and the power
of the local power supply.
This appliance is supplied with a
mains cable. It has to be supplied with
a correct plug which can hold the load
that the rating plate rates. Make sure
that you install the plug in a correct
socket.
Always use a correctly installed
shockproof socket.
Make sure that there is an access to
the mains plug after the installation.
Do not pull the mains cable to
disconnect the appliance. Always pull
the mains plug.
There is a risk of fire when the
appliance is in connection with an
extension cable, an adapter or a
multiple connection. Make sure that
the ground connection agrees with
the standards and regulations.
Do not let the power cable to heat up
to a temperature higher than 90° C.
Make sure that you connect
the blue neutral cable to the
terminal with a letter "N" on
it. Connect the brown (or
black) phase cable to the
terminal which has a letter
"L". Keep the phase cable
connected at all times.
8.6 Connection cable
To replace the connection cable use only
the special cable or its equivalent. The
cable type is: H05V2V2-F T90.
Make sure that the cable section is
applicable to the voltage and the
working temperature. The yellow / green
earth wire must be approximately 2 cm
longer than the brown (or black) phase
wire.
8.7 Building In
min.
55 mm
min.
650 mm
560 mm
480 mm
min.
450 mm
30 mm
10 mm
3 mm
11 mm
11 mm
A
A
B
A. supplied seal
B. supplied brackets
CAUTION!
Install the appliance only on
a worktop with flat surface.
8.8 Possibilities for insertion
The panel installed below the hob must
be easy to remove and let an easy access
in case a technical assistance
intervention is necessary.
ENGLISH