User manual

9.5 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK 1/100
mm
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Rapid 2,7 0,75 86 196 193
Semi-rapid 1,9 0,45 71 138 136
Auxiliary 1,0 0,33 50 73 71
9.6 Gas burners for LPG G30/G31 30/30 mbar - Cyprus only
BURNER NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK 1/100
mm
NOMINAL GAS
FLOW g/h
Rapid 2,7 0,75 86 196
Semi-rapid 1,9 0,45 71 138
Auxiliary 1,0 0,33 50 73
10. ENERGY EFFICIENCY
10.1 Product information according to EU 66/2014
Model identification HG694340NB
Type of hob Built-in hob
Number of gas burners 4
Energy efficiency per gas burner
(EE gas burner)
Left rear - Rapid 57.7%
Right rear - Semi-rapid 53.7%
Left front - Auxiliary not applicable
Right front - Semi-rapid 52,4%
Energy efficiency for the gas hob
(EE gas hob)
54.6%
EN 30-2-1: Domestic cooking appliances burning gas - Part 2-1 : Rational use of
energy - General
10.2 Energy saving
Before use, make sure that the burners and pan supports are assembled correctly.
Use cookware with diameters applicable to the size of burners.
Center the pot on the burner.
When you heat up water, use only the amount you need.
If it is possible, always put the lids on the cookware.
When the liquid starts to boil, turn down the flame to barely simmer the liquid.
If it is possible, use a pressure cooker. Refer to its user manual.
ENGLISH
17