User manual

To replace the connection cable
use only H05V2V2-F T90 or
equivalent type. Make sure that
the cable section is applicable to
the voltage load and the working
temperature. The yellow/green
earth wire (B) must be approxi-
mately 2 cm longer than the live
and neutral wire (A).
AB
WARNING!
A cut off plug inserted into a 13
amp socket is a serious safety
(shock) hazard. Ensure that the
cut off plug is disposed of safely.
The replacement of electric cable
must be carried out exclusively
by the service force centre or by
personnel with similar competen-
cies, in accordance with the cur-
rent regulations.
8.6 Building In
min. 45 mm
min. 650 mm
560 mm
min. 450 mm
40 mm
490 mm
+2
0
+2
0
min. 600 mm
A
A)
supplied brackets
CAUTION!
Install the appliance only on a
worktop with flat surface.
8.7 Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must
be easy to remove and let an easy ac-
cess in case a technical assistance inter-
vention is necessary.
min 20 mm
(max 150 mm)
40 mm
60 mm
a
b
a)
Removable panel
b)
Space for connections
Kitchen unit with oven
The hob recess dimensions must obey
the indication and the kitchen unit must
be equipped with vents to let a continu-
ous supply of air. The electrical connec-
tion of the hob and the oven must be in-
stalled separately for safety reasons and
to let easy remove oven from the unit.
50 cm
2
360 cm
2
180 cm
2
120 cm
2
14