Manual

complies with the standards and regu-
lations force.
The power cable must not touch any
hot parts.
The electrical installation must have an
isolation device which lets you discon-
nect the appliance from the mains at all
poles. The isolation device must have a
contact opening width of minimum 3
mm.
You must have the correct isolation de-
vices: line protecting cut-outs, fuses
(screw type fuses removed from the
holder), earth leakage trips and contac-
tors.
The connection cable parts must not be
heated to a temperature above 90°C.
Electrical Requirements
Permanent electrical installation must
comply with the latest I.E.E. Regulations
and local Electricity Board regulations.
For your own safety the installation must
be done by a qualified electrician (e.g.
your local Electricity Board, or a contrac-
tor who is on the roll of the National In-
spection Council for Electrical Installation
Contracting [NICEIC]).
The manufacturer declines any liability
if these safety measures are not ob-
served.
The appliance must be connected to a
230 V 50 Hz AC electrical supply.
Before activating the appliance, make
sure the electrical supply voltage is the
same as that indicated on the rating plate.
The rating plate is located on the bottom
of the appliance.
The appliance is supplied with a 3 core
flexible supply cord with a 3 amp plug. If
it is necessary to change the fuse, use a 3
amp ASTA-approved (BS 1362) fuse.
AB
C
D
E
A)
Green and Yellow
B)
3 amp fuse
C)
Brown
D)
Cord clamp
E)
Blue
Should the plug need to be replaced for
any reason, the wires in the mains lead are
coloured in accordance with the following
code:
Green and yellow - Earth
Blue - Neutral
Brown - Live
1.
Connect the green and yellow (earth)
wire to the terminal in the plug which
is marked with the letter 'E' or the
earth symbol
, or coloured green
and yellow.
2.
Connect the blue (neutral) wire to the
terminal in the plug which is marked
with the letter 'N' or coloured black.
3.
Connect the brown (live) wire to the
terminal in the plug which is marked
with the letter 'L' or coloured red.
There must be no cut or stray strands of
wire present. The cord clamp must be
correctly attached on the outer sheath.
WARNING!
Make sure that the cut off plug is
disposed of safely. A cut off plug
put into a 13 amp socket is a safe-
ty hazard. There is a risk of electri-
cal shock.
16