Operation Manual

9. TECHNICAL DATA
9.1 Hob dimensions
Width 576 mm
Depth 516 mm
9.2 Bypass diameters
BURNER Ø BYPASS 1/100 mm
Triple Crown 57
Semi-rapid 42
Auxiliary 32
9.3 Other technical data
TOTAL POWER:
Gas original: G20 (2H) 20 mbar = 8,6 kW
Gas replacement: G30 (3+) 28-30 mbar = 625 g/h
G31 (3+) 37 mbar = 614 g/h
Electric supply: 220-240 V ~ 50/60 Hz
Appliance category: II2H3+
Gas connection: G 1/2"
Appliance class: 3
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER kW MINIMUM POWER
kW
INJECTOR MARK
1/100 mm
Triple Crown 3,8 1,4 146
Semi-rapid 1,9 0,75 96x
Auxiliary 1,0 0,45 70
9.5 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK 1/100
mm
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Triple Crown 3,8 1,4 98 276 271
Semi-rapid 1,9 0,75 71 138 136
www.aeg.com16