CAUTION!
Make sure that the selected
power fits the house
installation fuses.
5.12 Power management
function
Cooking zones are grouped
according to the location and number
of the phases in the hob. See the
illustration.
Each phase has a maximum electricity
loading of 3600 W.
The function divides the power
between cooking zones connected to
the same phase.
The function activates when the total
electricity loading of the cooking
zones connected to a single phase
exceeds 3600 W.
The function decreases the power to
the other cooking zones connected to
the same phase.
The heat setting display of the
reduced zones changes between two
levels.
Power management function with
Power limitation function
When you set the Power limitation
function to 6.0 kW or less, power of the
hob is divided between all cooking
zones.
When you set the Power limitation
function to more than 6.0 kW, power of
the hob is divided between two cooking
zones in a pair.
5.13 Hob²Hood
It is an advanced automatic function
which connects the hob to a special
hood. Both the hob and the hood have
an infrared signal communicator. Speed
of the fan is defined automatically on
basis of mode setting and temperature
of the hottest cookware on the hob. You
can also operate the fan from the hob
manually.
For most of the hoods the
remote system is originally
deactivated. Activate it
before you use the function.
For more information refer
to hood user manual.
Operating the function automatically
To operate the function automatically set
the automatic mode to H1 – H6. The hob
is originally set to H5. The hood reacts
whenever you operate the hob. The hob
recognizes temperature of the cookware
automatically and adjusts the speed of
the fan.
Automatic modes
Auto-
matic
light
Boiling
1)
Frying
2)
Mode H0 Off Off Off
Mode H1 On Off Off
Mode
H2
3)
On Fan
speed 1
Fan
speed 1
Mode H3 On Off Fan
speed 1
www.aeg.com14