Owner's manual

After the check, activate the appliance.
The programme continues from the
point of interruption.
If the problem occurs again, contact the
service centre.
If the display shows other alarm codes,
contact the service centre.
12. TECHNICAL INFORMATION
Dimensions Width / Height / Depth 600 / 850 / 605 mm
Total depth 640 mm
Electrical connection: Voltage
Overall power
Fuse
Frequency
220-230 V
2200 W
13 A
50 Hz
Level of protection against ingress of solid particles
and moisture ensured by the protective cover, ex-
cept where the low voltage equipment has no pro-
tection against moisture
IPX4
Water supply pressure
1)
Minimum 0,5 bar (0,05 MPa)
Maximum 8 bar (0,8 MPa)
Water supply
2)
Cold water
Maximum load Cotton 10 kg
Spin speed Maximum 1400 rpm
1)
The appliance works correctly if the water pressure is not less than 0.05 MPa (0.5 bar).
If you can not connect the water inlet hose to the cold water tap of the primary hydraulic
system, connect it to your domestic cold water storage system.
Make sure not to have more than a distance of 5.02 m (16.5 ft) between the appliance
inlet hose and the bottom of the water storage tank.
2)
Connect the water inlet hose to a water tap with a 3/4'' thread.
13. ENVIRONMENT CONCERNS
Recycle the materials with the
symbol
. Put the packaging in
applicable containers to recycle it.
Help protect the environment and
human health and to recycle waste
of electrical and electronic
appliances. Do not dispose
appliances marked with the symbol
with the household waste. Return the
product to your local recycling
facility or contact your municipal
office.
28
www.aeg.com