User manual

Installation and Connection Instructions
45
Permissible water pressure
Water pressure must be equal to a least 1 bar (= 10N/cm
2
= 0.1 MPa),
and no more than 10 bar (= 100N/cm
2
= 1 MPa).
By more than 10 bar: connect a pressure reduction valve upstream.
By less than 1 bar: Unscrew the flexible inlet tubing on the magnetic
inlet valve on one side of the appliance and remove the flow meter
(thereby remove the sieve by means of a pair of pointed pliers and
then remove the rubber washer behind it). Remount the sieve.
Water feed
A flexible pressure tubing of 1.3m length is supplied.
If a longer feed tubing is needed, a complete VDE-approved tubing set
with mounted screw connections, supplied by our customer service,
should be used exclusively.
For washing machines without Aqua-Control, tubing sets are
available in lengths of 2.2m, 3.5m and 5m.
For washing machines with Aqua-Control, tubing sets are available
in lengths of 2.0m, 2.9m and 3.9m.
Attention! Under no circumstances may tubing be pieced together for
the purpose of lengthening!
3
Sealing rings are either inserted in plastic nuts of the tubing screw con-
nection or contained in an accompanying packet. Do not use other
seals.
0 1. Connect the angled hose connector to the
machine.
Attention! Plastic nut at the tube coupling
may only be hand tightened.