Operation Manual

6 V
6,5 V
7,1 V
6,7 V
6,7 V
2,7 A
2,5 A
10,0 A
2,5 A
2,0 A
S
T
10.00
11.00
12.00
26
Figure 3
6 V charging mode
Phase 4: Slow charging
Phase 5: Trickle charging
Phase 6: Battery charge is at 100 %
Phase 3: Rapid charging up to 90 %
Phase 2: Gentle charging
Phase 1: Battery detection
3.5 6-setting charging mode diagram for 6, 12 and 24 V batteries
T. The battery voltage is less
than 3.5 V in 12 and 24 V
batteries. Battery defective.
S. Charger is overheated.
The equipment will switch off
above 85 C.
°
0
5
25
75
95
100
97100_Ladeger󾜀t _LP_10.0 Manual _09_12_2011_print