User manual

23
Programming options
Objective Implementation
Permanently program
in the audible signal
which reminds you that
the programme is com-
plete.
1. Turn the programme selector to any programme.
2. Press the AUDIBLE SIGNAL (ZOEMER) button and hold
down for approx. 5 seconds.
A brief signal sounds several times. The AUDIBLE SIGNAL
(ZOEMER) display flashes several times.
The setting is permanently programmed.
The setting is cancelled as described under 1 and 2.
Adjust detection of de-
gree of drying:
If the laundry is slightly
drier or slightly damp-
er at the end of the
programme than with
the standard setting.
1. Turn the programme selector to any programme.
2. Press the AUDIBLE SIGNAL (ZOEMER) and SENSITIVE (BE-
HOEDZAAM) buttons at the same time and hold down for
approx. 5 seconds.
The current setting is displayed on the programme
progress display:
– END (EINDE) display: Setting for drier laundry
– COOLING (AFKOELEN) display: Standard setting
– DRYING (DROGEN) display: Setting for damper laundry
3. Press the START/PAUSE (START/PAUZE) button until the
setting required appears on the programme progress dis-
play.
4. Turn the programme selector to OFF (UIT).
The setting is permanently programmed.
If the EMPTY WATER
(RESERVOIR) display is
to remain permanently
deactivated when us-
ing an external con-
densate drain.
1. Turn the programme selector to any programme.
2. Press the SPECIAL CARE (LAGE TEMP.) and DELAY TIMER
(STARTTIJDKEUZE) buttons at the same time and hold
down for approx. 5 seconds. The EMPTY WATER (RESER-
VOIR) display flashes briefly.
The EMPTY WATER (RESERVOIR) display is permanently
deactivated.
Settings may be cancelled as under 1 and 2, but the EMPTY
WATER (RESERVOIR) display is briefly illuminated (instead of
flashing).