10. Appliance installation
10.1 Wall mounting
!
Material losses
Only mount the natural stone heater on a at wall, as
otherwise cracks may develop in the natural stone
panel due to stresses. In the event of unevenness
in the mounting wall, level the surface before tigh-
tening the xing screws.
!
Material losses
Do not tilt or tip the natural stone heater. Otherwise,
it may break.
!
Material losses
If the xing screws are over-tightened, the rawl plugs
in the natural stone panel may over-rotate and be-
come loose.
» Measure dimensions a and b for the drill holes on the
natural stone heater.
» Based on the measurements, drill the holes in a wall
with sufcient load-bearing capacity. Maintain a saf-
ety margin of 100 mm on all sides (e.g. dimension b
+ 100 mm).
» Screw the hexagon screws far enough into the drill
holes that the natural stone heater can still be hoo-
ked over the screw heads with the open slots in the
wall mounting brackets.
» Hang the natural stone heater. Tighten the hexagon
screws. Relieve any stress by slightly loosening the
xing screws in the natural stone panel. Then retigh-
ten the xing screws.
10.2 Power supply
!
Material losses
Only shorten the power cable far enough to be able
to hang the natural stone heater without disconnec-
ting the power cable.
Only connect the natural stone heater to an alternating
voltage of 230 V / 50 Hz.
NNL’ L
NSH
L
N
PE
26_07_30_0010
11. Initial start-up
!
Material losses
When heating up the natural stone heater for the rst
time, observe a maximum heat-up time of 20 minu-
tes. Then let the panel cool down for at least 60 mi-
nutes.
» Perform this process one more time.
In the rst two days of use, heat up the natural stone
heater step-by-step to the required room temperature.
This way, you avoid hairline cracks. If hairline cracks do
develop, these are harmless and do not impair the func-
tion or the safety of the natural stone heater.
12. Handover
» Explain the functions of the appliance to the user.
Draw special attention to the safety instructions.
» Hand over the operating and installation instructions
to the user.
13. Specication
13.1 Dimensions and connections
B
H
230 V
H
23
H
23
70
b
35
40
a
26_07_30_0013
13.2 Minimum clearances
100 mm
500 mm
100 mm100 mm
100 mm
100 mm
300 mm100 mm
26_07_30_0003