Operation Manual

9
English
For the Fitter
2. Installation instructions
Installation, electrical connection, and first start-up must be carried out by a qualified installer
who is registered by the appropriate electricity supply company, under observance of these
installation instructions.
2.1 Unit construction
1 Natural stone slab
2 Wall mountings
3 Heating cable, embedded
4 Mains connection cable
5 Spacer bolts
6 Wall mounting securing screw
7 Hexagonal screw
A channel system is cut into the back of the natural stone slab, into which a heating conductor
with two automatic-reset safety thermal cut-out is inserted.
To cover this over, the channel system is finally filled with marble bonding cement.
2.2 Technical Data
Type NSH 35 NSH 65 NSH 85 NSH 115 NSH 145
Stone type (VA / JA / VO / MC / PR / SA / PA / LA / ...)
Rated power W 350 650 850 1150 1450
Rated voltage 1/N ~ 230 V 50 Hz
Dimensions
H x W x D mm 400 x 600 x 30 400 x 1000 x 30 500 x 1000 x 30 600 x 1000 x 30 600 x 1250 x 30
Weight kg 21 35 44 52 62
Mains connection Connection lead approx. 100 cm; permanent connection; 2 x 0.75 mm²
Protection class II
Protection mode IP 25, water jet protection
Test certificates VDE, EMV, GS, CCA, CE
02 Inhalt NSH.p65 19.05.2005, 12:119