8.3 Electrical connection
Use a power cable of H05VV-F or higher.
Connect the appliance to a socket sup-
ply line. If there is no socket supply line,
the electrical installation must have an
isolation device which lets you discon-
nect the appliance from the power sup-
ply. The isolation device must have a
contact opening width of minimum 3
mm (in reference to NIN SEV 1000). The
customer must have a socket for the
electrical connection that is accessible
and outside the coordination room. The
length of the connection cable must be
approximately 120 cm with lines connec-
ted directly to the power supply.
1
2
3
5
4
L1
Netz: 400V 3N~ 230V~
Netz: 400V 2N~
Heizkörperspannung 230V
Tension des C.D.CH. 230V
Tensione elementi radianti 230V
230V 3~
L2
N
L3
1
2
3
5
4
L
L1
N
1
2
3
5
4
L1 L2
N
1
2
3
5
4
L1 L2
L3
315171917/2.98
Only a qualified person can con-
nect the appliance to the elec-
tricity supply.
1.
Do the electrical connections as in
the connection illustration.
Connection diagram
Phase definitions: L1, L2, L3 (or R, S,
T).
2.
Secure the cable grip.
WARNING!
If service is required always dis-
connect the appliance from the
power supply.