Operating instructions

22
i
In this connection, note
the special property of the
two additional output sockets identified with
“SURGE ONLY” (chapter 4.3 / no. 7 / pg. 19).
These are always live irrespective of the other
outputs. They are not backed up by the UPS, nor
can they be switched off using the main switch of
the UPS. It is intended for loads that should be
protected against overvoltage but do not
necessarily need a continued power supply
(emergency power) in case of a mains failure.
Limit the power to max. 1000 W.
5.5 RJ11 and RJ45 Data Line Protection
(Modem/ Phone/ Fax/ Network)
Connect the incoming phone line/network cable into the “IN”
connection on the back of the PROTECT A.
modem line
Incomin
g
phone
,
fax,
Connect the data terminal unit (phone, fax, modem) to the
“OUT” socket.
i
The data line protection supports networks with
transmission rates between 10 and 100 Mbit/s.
Data lines are not supplied with the UPS.
5.6 Communication Connection,
Connection with USB or Serial Cable
In order to allow unsupervised shutdown of the operating
system, connect the RS232 or USB cable as shown in the
drawing.
The USB connection is automatically detected.
Incoming data line