For the Fitter
Wire the room temperature regulator according to the circuit diagram
(see circuit diagram, page 6)
- Short black wire of switch 2 (S2) to room temperature regulator 5 (N6)
- Long black wire of switch 2 (S2) to (L) terminal strip X1
- Black wire (long) from heating resistor 6 (E9) to room temperature regulator 5 (N6)
- Blue wire from heating resistor 6 (E9) to (N) terminal strip X2
- Black wire from regulator 5 (N6) to X2 LE (from above)
Screw the radio interference suppressor (7) to the top part of the angle plate
(above terminal strip X2) with the screw provided
Wiring of the radio interference suppressor:
- Blue wire to X1 L top (double assignment)
- Black wire to X2 L top (double assignment)
- Fix the cables in the existing cable strap in the switching area behind the angle plate.
All switching wires must be fixed in the switching area in such a way that they neither come
into contact with the right side wall nor can be touched through the ventilation slots. They
must not be near to the cable opening either.
Stick the valid circuit diagram over the circuit diagram on the right side wall, mark installation
and stick the control panel label to the outside of the right side wall.
Mount the right side wall. Fix the fastening screw with toothed washer