1. Tilt back the appliance carefully so
that the compressor cannot touch
the floor.
2. Remove the plinth.
3. Unscrew and remove the lower
hinges.
3
4
1
5
2
4.
Remove the door.
5. Unscrew the upper pin and screw it
on the opposite side.
2
1
6. Refit the door.
Make sure the edge of the door is
parallel with the edge of the top.
7. Unscrew the pin (A) and screw it on
the opposite side.
8. Remove the cap (B) and position it
on the opposite side.
A
B
9. Screw the lower hinges.
10. Refit the plinth.
11. Stand the appliance upright.
12. Fit the handle on the opposite side
and put the plastic caps (contained in
the instructions bag) in the free
holes.
CAUTION!
Reposition, level the
appliance, wait for at least
four hours and then connect
it to the power socket.
Do a final check to make
sure that:
All screws are tightened.
The magnetic seal
adheres to the cabinet.
The door opens and
closes correctly.
If the ambient temperature
is cold (i.e. in Winter), the
gasket may not fit perfectly
to the cabinet. In that case,
wait for the natural fitting of
the gasket. In case you do
not want to carry out the
above mentioned
operations, contact the
nearest After Sales Service
Force. The After Sales
Service specialist will carry
out the reversibility of the
doors at your cost.