User manual

31
If installation next to a source of heat is unavoidable, the following
minimum clearances must be maintained at the sides of the appliance:
– for electric cookers 3 cm;
– for oil and coal fired ranges 30 cm.
If these clearances cannot be maintained a heat insulating pad is requi-
red between the cooker and the refrigeration appliance.
Remove transport safeguard
The appliance as well as interior accessory parts are safeguarded for
transport.
Remove all tape and pads from the interior of the appliance.
Installation
Installation Location
The appliance should be set up in a well ventilated, dry room.
Energy use is affected by the ambient temperature.
The appliance should therefore
not be exposed to direct sunlight;
not be installed next to radiators, cookers or other sources of heat;
only be installed at a location whose ambient temperature corre-
sponds to the climate classification, for which the appliance is desi-
gned.
The climate classification can be found on the serial plate, which is
located at the left on the inside of the appliance.
The following table shows which ambient temperature is correct for
each climate classification:
Climate classification for an ambient temperature of
SN +10 bis +32 °C
N +16 bis +32 °C
ST +18 bis +38 °C
T +18 bis +43 °C