Operating instructions

Installation
10 818 35 64-01/5
The following table shows which ambient temperature is correct for
each climate classification:
If installation next to a source of heat is unavoidable, the following
minimum clearances must be maintained at the sides of the appliance:
– for electric cookers 3 cm;
– for oil and coal fired ranges 30 cm.
If these clearances cannot be maintained a heat insulating pad is
required between the cooker and the refrigeration appliance.
The Refrigerator needs Ventilation
Air is fed under the door through the vent
slots in the base and is exhausted upwards
along the back wall. To ensure proper air
circulation never cover or alter the vent
openings.
Important! If the appliance is installed
under a hanging cabinet, a clearance of at
least 10 cm between the top of the
appliance and the cabinet above it must
be maintained.
Please check whether, after installing
your appliance and especially after
rehingeing the door, the door seal seals right round. An untight door
seal may lead to heavy frosting and a higher power consumption (see
also "Something not working“).
Appliance Alignment
0 1. The appliance level please compensate for unevenness in the floor by
turning the two adjustable feet at the front.
Climate classification for an ambient temperature of
SN +10 to +32 °C
N +16 to +32 °C
ST +18 to +38 °C
T +18 to +43 °C