Operation Manual
1. Open loading door
2. Pull off adhesive strips from inside appli-
ance on top of drum.
3. Remove foil hose and polystyrene pad-
ding from the appliance.
Electrical connection
Details on mains voltage, type of current and the fuses required should be taken from
the rating plate. The rating plate is fitted near the loading aperture (see “Product descrip-
tion” chapter).
Connect the machine to an earthed socket, in accordance with current wiring regulations.
WARNING!
The manufacturer declines any responsibility for damage or injury through failure
to comply with the above safety precautions.
Should the appliance power supply cable need to be replaced, this must be car-
ried out by our Service Centre.
The appliance is supplied with a 13 amp plug fitted. In the event of having to change the
fuse in the plug supplied, a 13 amp ASTA approved BS 1363/A fuse must be used.
The wires in the mains lead are coloured in ac-
cordance with the following code:
1 Blue - Neutral
2 cord clamp
3 Brown - Live
4 Green and Yellow - Earth
The wire coloured green and yellow must be con-
nected to the terminal marked with the letter
«E» or by the earth symbol
or coloured green
and yellow.
The wire coloured blue must be connected to the
terminal «N» or coloured black.
The wire coloured brown must be connected to
the terminal marked «L» or coloured red.
Upon completion there must be no cut, or stray strands of wire present and the cord
clamp must be secure over the outer sheath.
WARNING!
A cut off plug inserted into a 13 amp socket is a serious safety (shock) hazard.
Ensure that the cut off plug is disposed of safely.
WARNING!
The plug must be accessible after installing the machine.
1
2
3
4
Installation
7