User manual

11.2 Drum internal lamp
This appliance has an internal lamp that
comes on when you open the door and
goes off when the door is closed.
WARNING!
Do not look directly into the
beam of the lamp.
To replace the internal lamp,
contact the service centre.
Disconnect the mains plug from
the mains socket before the re-
placement of the internal lamp.
12. TECHNICAL INFORMATION
height x width x depth 850 x 600 x 600 mm (maximal 640 mm)
drum volume 118 l
maximum depth with the load door
opened
1090 mm
maximum width with the load door
opened
950 mm
adjustable height 850 mm (+ 15 mm - feet regulation)
the appliance weight 43 kg
maximum load 8 kg
voltage 230-240 V
frequency 50 Hz
total power 2250 W
type of use Domestic
permitted ambient temperature + 5°C to + 35°C
13. INSTALLATION
13.1 Appliance positioning
The tumble dryer must be installed in
a clean position, where dirt does not
collect.
Air must flow freely around the appli-
ance. Make sure that the front airflow
slots in the bottom of the appliance
are not blocked .
To keep vibration and noise at the
minimum, when the tumble dryer op-
erates, it must be put on a stable and
flat surface.
When the appliance is put in its per-
manent position, check it is fully level
with the aid of a spirit level. If it is not,
adjust the feet until it is.
Do not remove the feet. Do not de-
crease the floor clearance through
thick carpets, plank of wood or piece
of wood. This can increase the heat
which can cause interference with the
operation of the appliance.