Operation Manual

22
For the Fitter
2. Installation instructions
2.1 Technical Data
Model WSP 600 HF
Storage Capacity 48 kWh
Rating 6,0 kW
Voltage 3/N/PE ~ 400 V
Dimensions Height: 1056 mm
Width: 670 mm
Depth: 350 mm
Weight ca 330 kg
Day-acting element 1.0 kW
Core-brick packs 3 x SP26 and 6 x SP27
2.2 Heater Positioning and Installation
The electrical installation of this heater must be approved by your local electricity company.
The installation must be carried out by a competent electrician.
Electrical installation and local safety regulations must also be adhered to.
If heaters are to be installed in commercial or public buildings such as hotels, holiday homes or
apartments, schools, administrative buildings etc., a special warning label is to be attached to the
top of the heater. This label is available from your local contractor.
2.2.1 Procedures to be followed
All National and Local Safety Codes should be adhered to both at the planning and installation
stages.
2.2.2 Choosing the Heater Position
The heater can be positioned anywhere within the room to be heated.
The floor and/or the wall must be able to take the weight of the heater. Please, therefore, note
carefully the weights given in the Technical Data section of this instruction. If in doubt, consult a
building engineer or architect.
AEG high line storage heater generally need no protective underboard when standing on normal
flooring, as long as this is flat and smooth and can withstand temperatures of 80 °C minimum.
In the case of soft, load-sensitive or non-heat-resistant floors or carpeting, as well as to even out
any surfaces, it is advisable to first put down a protective board the size of the underside of the
heater. When using high- or thick-pile carpeting a protective board should definitely be used.
For appliances without integral room thermostats, the wall-mounted room thermostat should
be mounted preferably on an internal wall, at least 2.5 m from the heater and at a height of
approx. 1.5 m.