For the Fitter
Fitted components:
B1 Charge thermostat
E1 Storage heating elements
F1 Charge limiter
F3 Safety thermostat for fan
M1 Fans
R1 Charge control resistance
R2 Fan compensatory resistance
X1 Terminal block current feed
X2 Terminal strip for power draw setting
X3 Terminal block for control cables
Accessory:
B2 Room thermostat
E2 Day-acting element
F2.1 DAE control thermostat
F2.2 DAE safety cut-out
K1 Thermal relay
2.3.6 Circuit Diagram WSP 600 HF
Power draw
The terminal strip X2 can be found on the inner side
panel on the left side of the heater.
Tick connected power
setting!
Electric storage heater
Distributor
panel
On site wiring
to a further
storage heater
Distributor
panel
Distributor
panel
Charge control
cable
(if applicable)
Load-current to storage heater
3/N/PE ~ 400V
to further
storage heaters
Control current
to storage heater
1/N/PE ~ 230V
e.g. 5 x 1,5 mm
2
Fig. 10
Caution! Even if the main circuit breakers are switched off, some terminals carrying
on-peak current, especially terminals A1/Z1 and A2/Z2 can still be live.