Owner`s manual

46
SELECT BUTTON:
WHEN PHONE DEAD
The arrow keys are used to select from a list of event buttons:
WHEN ENERGY LO
WHEN ENERGY MID
WHEN ENERGY HI
WHEN ENERGY CRIT
WHEN PHONE DEAD
WHEN PHONE RING
WHEN PHONE OFFHK
WHEN PHONE ONHOOK
WHEN AC PWR OFF
WHEN AC PWR ON
WHEN BATTERY LOW
WHEN BATTERY OK
WHEN DCM FAIL
WHEN DCM OK
Edit Program Command
Selecting 2 (CMD), from the Edit Program menu, allows the commanded action for the program to be specified. The following
menu is displayed:
1=CONTROL 2=SECURITY
3=BUTTON 4=ALL
5=TEMP 6=ENERGY
8=MESSAGE
After the command is specified, the display returns to the Edit Program menu:
Program Control Commands
Press the 1 (CONTROL) key to command lights and appliances. Specify the desired command - See Control.
Porch Light (Unit Name)
0=OFF 1=ON 2=DIM 3=BRT
Porch Light (Unit Name)
4=LVL 5=RMP 9=TIM #=STA
If the selected unit is part of a House Code that is configured to use the Compose Format, the second page of the menu is
modified to allow Scene commands. Consequentially, the Level and Ramp Commands are removed from the menu.
Entry Lights (Unit Name)
4=SCN 9=TIM #=STA
If the selected unit is not capable of dim and bright commands, only a single menu is shown.
SPRINKLER 1 (Unit Name)
0=OFF 1=ON 9=TIM #=STA
Program Security Commands
Press the 2 (SECURITY) key to arm and disarm the security system, or to bypass and restore an individual zone. The following
menu is displayed: