Specifications

LBI-33057
3
DESCRIPTION
This manual outlines service procedures for the Aegis
M-PA UHF portable radios. Information includes radio dis-
assembly and reassembly procedures, RF alignment and RF
component-level troubleshooting steps. Information is also
included for tracking and channel data, surface mounted
component replacement, weatherproofing procedures, RF
retuning procedures, and service data on the batteries.
Module and integrated circuit data sheets for the RF Board
components are listed at the end of this manual.
In order to perform many of the following alignments,
tests and troubleshooting checks, it will be necessary to
(re)program the radio. Further programming information
can be found in the Programming Manual and software.
See LBI-39157 for service information on the
Control Board. See LBI-38834 for service infor-
mation on the Front Cover Assembly.
TEST EQUIPMENT
The following is a list of test equipment which may be
required to troubleshoot and/or align the portable radio.
GENERAL.
RF Signal Generator
RF Wattmeter with 10-Watt capability
Audio Distortion Analyzer with Vu Meter
Oscilloscope with x1 and x10 Probes
Audio Oscillator
Frequency Counter
Modulation Analyzer
SINAD Meter
Regulated DC Power Supply, 5 - 9 Vdc adjustable,
5 amperes maximum
Digital Muitimeter
SPECIALIZED
K19/A4WX01542 RF Test Cable (UDC
mount)
K19/A4WX01543 Battery Eliminator
("Dummy Battery")
K19/A4WX01544 RF/Logic Extender Cable
K19/A4WX01604 Discharge Analyzer (checks
battery pack capacity and
battery chargers)
LBI-38518 Front Cover Test Accessory
Kit Manual
SPK9010 Front Cover Test Accessory
Kit:
19D902562P5 Front Cover Test Cable
19D902562P1 LCD Extender Plate &
Clamp
19D902562P2 LCD Test Cable
19D902562P6 Test Program Diskette
SPK9011 Front Cover Test Accessory
Kit:
19D902562P3 Adapter Board
19D902562P4 Control Board Extender
ST3559 RF Antenna Adapter (top
jack to BNC female)
TQ-0609 Test Box (simulates all exter-
nal UDC options)
19B219079P1 Alignment Tool, 0.1" slotted
(metal) tips
19B801640P1 Alignment Tool, 0.1" slotted
tips.
In addition to the above listed equipment, Aegis opera-
tional tests will require the appropriate test equipment and
a second Aegis portable or mobile radio. Also, radios will
require access to a local trunked site and a second portable
or mobile (trunked) radio to test trunked mode operation.
NOTE