I ) RECORD USER CARDS – Feature Group 1
There are 5 Storage Groups available for storing total 500 User Cards. For easy management, each
group accommodates 100 user cards maximum. The indicator LED of the storage group is ON for
vacancy available and flashing for vacancy full.
This system is designed for small office or home that does not have large number of users. It is
suggested to put user cards evenly into the 5 Storage Groups. For example, evenly put 5 User
Cards each into the 5 groups for an office of 25 staff. In case group clearing is required, only to clear
the group that holds the lost card.
It is suggested to make a list recording the User Number and the Name of the card holders for each
of the Storage Groups before programming. It will be helpful to record the cards smoothly and also
to trace them from the system afterward in case a card is lost.
Storage Group 3....5
Storage Group 2
--
--
-
Accounts Dept
Eng Dept
Eng Dept
Admin Dept
Sales Dept
RemarkName of Holder
Sales Dept
Mary
Paul
Alan
Nancy
Tracy
John
-
-
-
Storage Group 1
User Number
6
5
4
3
2
1
100
10
Procedures
1) Read Master Card 1 Time to set system to Feature Group 1 – Record User Cards.
....Response : Status LED (blue)starts to flash during programming mode and group LED 1 is ON.
........................After 2 seconds, the system confirms the selection with 2 beeps and the 5 group
........................LEDs flashing for five storage groups available.
2) Press BELL button to select one of the 5 Storage Groups for storing the User Cards.
....Response : The selected group LED is ON for vacancy available. After 2 seconds the system
........................confirms the selection with 2 beeps.
........................The selected group LED stays flashing for vacancy full without confirmation.
3) Record the User Cards
....They can be read and appended one by one into the desired Storage Group.
....Response : 2 Beeps confirm successful for each card recording.
4) Read Master Card 1 Time to exit Programming Mode.
....Response : 2 Beeps confirm reader back to normal operation.
NOTE:
Press BELL button to select other Storage Groups with the above procedures 2 & 3 before close
...of programming mode.
All the User Cards must be unique in the system. Repeat recording of same card into other
...groups will be rejected. One long beep indicates rejection of a repeated card.
Exit
Programming Mode
Record
New User Cards
Select Desired
Storage Group 1-5
Read Master Card 1 Time
Set System in Feature Group 1
4321
15
V ) CREATE / DELETE SUPER USER CARDS -- Feature Group 5
The Super User cards are prepared for the owner or the trustworthy executives, which have TWO
functions that are system lock-up and door open. Total five Super User Cards can be created
with one for each user group.
Lock-up the system during the time of “after-office-hours” or the house of nobody inside. Lock-up
Release is in toggle manner.
Release the system from Lock-up instantly at anytime.
Act as Owner’s private user card for door open at any condition including in the system lock-up
period.
Procedures
1) Read Master Card 5 Times to set system to Feature Group 5 – Create / Delete Super User
....Cards.
....Response : Status LED (blue) starts to flash during programming mode and group LED 5 is ON.
........................After 2 seconds, the system confirms the selection with 2 beeps and the group LED
.......................1 & 2 flashing for the two options available.
A) Create Super User Card(s) – Option 1
2) Press BELL button to select Option 1 -- Create
....Response : LED 1 is ON. After 2 seconds, the system confirms the selection with 2 beeps and
........................then the 5 LEDs flashing.
Exit
Programming Mode
Select
Location 1-5
Record
Super User Cards
Select
Option 1 -- Create
Read Master Card 5 Times
Set System in Feature Group 5
54321
3) Press BELL button to select a location 1-5 for one of the Super User Cards.
....Response : The selected LED stays ON. After 2 seconds, the system confirms the selection with
........................2 beeps.
4)
Read a new User Card once to make it Super User Card
....Please marked it Super User with location number; location 1 belongs to Storage Group1.
....Response : 2 Beeps confirms successful.
....Note: a) Repeat procedures (3) & (4) to record Super User Cards at other locations if required.
.................
..Total 5 Super Cards can be made.
.........
.....b) The new card replaces the old card if there was an old card in the location.
5) Read Master Card 1 Time to exit Programming Mode.