User's Manual
8
The First Step before Programming- Make A Master Card
● The system needs a Master Card to set it into programming mode. Before programming, it is
iiIInecessary to make a Master Card by the owner.
● In case the Master Card is lost, it is necessary to make a new Master Card to replace it. Once a
iiIInew Master Card is made, the old one is invalid.
Procedures of Creating A New Master Card with CMC Jumper:
1) Switch OFF power to the reader completely
2) Put the CMC Jumper from OFF to ON position (The jumper is on the circuit board)
3) Switch ON power again.
iiiiiResponse : The reader gives continuous beeps. The Status LED (blue) starts to flash for one
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiminute. This is the allowed time for making a Master Card.
4) Put the jumper back to OFF position.
iiiiiResponse : The beep stops.
5) Read an EM card (a new EM card or keyfob).
iiiiiResponse : Two beeps confirm reading successful.
6) Press the Bell button 1 Time to save the Master card and exit CMC mode.i
iiiiiResponse : Two beeps confirm reader back to normal operation. The Status LED is ON.
7) Label the card as MASTER.
iiiiiIt is a card for programming authorization purpose. Do not mix it with other User Cards and keep
iiiiiit in a safe place.
CREATE A MASTER CARD (CMC)
NOTE:
The system will get stuck and the status LED will turn OFF if the Master Card can not
be made within the allowed time of one minute. It is necessary to repeat procedures 1-6
and try again.
CMC JUMPER
CMC
2. OFF
1. ON
1) Read User Card to Open Door
● Read User Card once.
● Two beeps confirm success of reading a valid user card and its group LED turns ON during the
iiiidoor lock strike.
● Five beeps are generated for invalid card.
2) Read Super User Card to Open Door
● Read Super User Card twice within 3 seconds.
● Two beeps confirm success of reading a valid super user card and its group LED turns ON during
iiiithe door lock strike.
● Five beeps are generated for invalid card.
iiiiNote:
iiiiSuper User Card is valid all the time in both Normal & System Lock-up conditions.
3) Read Super User Card to Make System Lock-up
● Read Super User Card once, and then, press BELL button once within 3 seconds.
● Two beeps confirm success. The Status LED (blue) flashes slowly (0.5sec ON, 1sec Off) during
iiiithe system lock-up in effect.
● Five beeps are generated for invalid card.
iiiiNote:
● During the lock-up time, the Status LED (blue) flashes slowly and the reader refuses all the
iiiigeneral user cards except the Super User cards.
● The Egress Button works normally all the time and is not affected by the lock-up function.
● The Door Bell button works normally all the time and is not affected by the lock-up function.
4) Read Super User Card to Release System Lock-up
● iRead Super User Card once, and then, press the BELL button once within 3 seconds.
● Two beeps confirm success. System goes back to normal operation and the Status LED (blue)
iiiiiturns ON from flashing.
●iiFive beeps are generated for invalid card.
OPERATION
17
FCC STATEMENT
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause
undesired operation.
2. Changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.