User's Manual

10
CONNECTION TERMINALS
NOTE:
DRY CONTACT
A dry contact means that no electricity is connected to it. It is prepared for free connections.
N.C.
Normally Closed, the contact is closed circuit at normal state. It is open circuit when active.
N.O.
Normally Open, the contact is open circuit at normal state. It is closed circuit when active.
TRANSISTOR OPEN COLLECTOR OUTPUT
An open collector output is equivalent to a Normally Open (N.O.) contact referring to ground similar to a relay
contact referring to ground. The transistor is normally OFF, and its output switches to ground (
-
) when active. The
open collector can only provide switching function for small power but it is usually good enough for controlling of
an alarm system. The maximum rating is 24V DC/100mA Sink
OPEN COLLECTOR
OUTPUT ----
Output switches to
ground when activated
N.O. CONTACT
OUTPUT ----
Output switches to
ground when activated
EQUIVALENT
-
ALARM O/P
-
KEY ACT O/P
-
N.O.
-
COM
-
N.C.
-
N.O.
-
COM
-
N.C.
-
N.O.
-
COM
-
N.C.
-
TAMPER
-
GND(
-
)
-
DOOR SENS
-
O/P 1 INHIB
-
INT. LOCK
-
DU OUT
-
DOOR BELL IN
-
EG IN
-
DATA I/O
-
KEYPAD PWR
-
GND(
-
)
-
12-24V DC
OPEN COLLECTOR OUTPUT
OPEN COLLECTOR OUTPUT
1A RELAY DRY CONTACTS
FOR AUXILIARY CONTROL
1A RELAY DRY CONTACTS
FOR AUXILIARY CONTROL
5A RELAY DRY CONTACTS
FOR DOOR STRIKE
OPEN COLLECTOR OUTPUT
OPEN COLLECTOR OUTPUT
INPUT/OUTPUT FOR SPLIT-DECODED SIGNALS
POWER OUTPUT FOR KEYPADS
COMMON GROUND
POWER INPUT FOR SYSTEM
N.C. SW
COMMON GROUND
N.C. SW
N.O. SW
N.O. SW
N.O. SW
OUTPUT 1O UTPUT 2O UTPUT 3
CONFIGURATION OF THE OUTPUT MODES OF OUTPUT 1, 2 AND 3 (Locations 51, 52 & 53)
The three relay outputs of this keypad are programmable for Start/Stop or Timing modes. Apart from the door access
control, alarm arm-disarm control, they are also universal timers for automatic operators in industry with their
99,999 seconds (over 24 hours) programmable timer.
OUTPUT LOCATIONS
51
-- Location for Output 1
52
-- Location for Output 2
53
-- Location for Output 3
OUTPUT MODE & TIMING
0
– Start /Stop Mode (Toggle)
The number 0 sets the output to the Start / Stop mode. The output Starts when an User PIN and/or Card is entered/
read; the output Stops when an User PIN and/or Card is entered/read again.
1
-
99999
Seconds Momentary --- (Default -- Momentary 5 Seconds)
The output can be set in Momentary Mode with the time of 1 second to 99,999 seconds. The output will reset
automatically when the time expires OR it can be RESET manually at anytime with the Super User Code that
operates the desired output before the end of the time.
Example : Reset Output 1 --
#
1
------------- Output 1 resets
Reset Output 2 --
#
2
------------- Output 2 resets
Reset Output 3 --
#
3
------------- Output 3 resets
PERSONAL SAFETY AND SYSTEM LOCK-OUT (Location 60)
SAFETY & LOCK-OUT OPTIONS
The Options are represented by their Mode Numbers in programming. They are described below:
1
--- After 10 successive false Card/User Code trials, the keypad locks during 60 seconds. -- (Default)
2
--- After 10 successive false Card/User Code trials, activates the Duress output to switch to (
-
) ground.
The Duress Output can be released with any user PIN or Card in the User Group 1 or Super User PIN.
5
-
10
--- Selection of after 5 to 10 successive Card/User Code trials, the keypad locks during 15 minutes.
The keypad can be reset to release the lock-out with the “Super User Code” in the following way.
Example : Release the lock-out --
#
9
00
--- Disappearance of all the above lock-out securities.
SUPER USER CODE
SUPER USER CODE
SUPER USER CODE
1 to 2 Digits
LOCK-OUT MODES VALIDATIONLOCATION
60 #
SUPER USER CODE
OUTPUT MODE & TIME VALIDATIONLOCATIONS
51
-
53 0
or
1
-
99999 #
33
MASTER
INDIVIDUAL