THE AUDIBLE AND VISIBLE SIGNALS
STATUS AUDIBLE SIGNALS MAINS LED SIGNALS
1) Power-up Delay (5 Seconds) Continuous Beeps Continuous Fast Flashes
2) Power-up Delay (1 Minute)* Continuous Beeps Continuous Fast Flashes
3) System In Standby Mode OFF 1 Flash / Second
4) System In Standby Mode* OFF ON
5) Keypad In Programming Mode OFF 1 Flash / Second
6) Successful Command from RF Key 2 Beeps 2 Flashes
7) Output Relay Active (From Keypad) 1 Long Beep or 2 Short Beeps No Signal
8) Egress Delay Warning Fast Beeps Nil
9) Door Forced Open Warning Fast Beeps + Alarm Output Nil
10) Door Propped-up Warning Fast Beeps Only Nil
11) Alarm Output Warble Tone Siren Nil
12) Door Chime Dual Tone Door Chime Nil
* Stand Alone Mode
THE ALARM OUTPUTS & WARNINGS
1) Tamper Alarm:
a) The alarm is triggered via the “Tamper In” terminal
b) Alarm Output and Internal Siren activate
c) The alarm period is fixed in 3 minutes for Stand Alone Mode
d) It can be reset with Super User Code # 1 or an user Code/Card in Group 1 in Split-decoded Mode
The Following Alarm & Warning Are Available in Split-decoded Operation Mode Only
2) Egress Delay Alarm:
a) The Egress Delay Alarm is enabled by programming from keypad at Programming Location 90
b) The alarm activates during the Egress Delay period and it stops at the expiry of the Egress Delay
c) Alarm Output and Internal Siren activate
3) Egress Delay Warning:
a) The Egress Delay Warning is enabled by programming from keypad at Programming Location 90
b) The warning activates during the Egress Delay period and it stops at the expiry of the Egress Delay
c) The warning beep is given by the internal buzzer only
4) Door Open Alarm (Designed for Emergency Door):
a) The Door Open Alarm is enabled by programming from keypad at Programming Location 91
b) Alarm Output and Internal Siren activate
c) Alarm happens in door forced to open or normal open with Egress Button
d) No Alarm happens in door open with User PIN or Card
5) Door Forced Open Alarm:
a) The Door Forced Open Alarm is enabled by programming from keypad at Programming Location 80
b) Alarm Output and Internal Siren activate
c) Alarm happens in door forced to open only
d) No Alarm happens in door open with Egress Button, User PIN or Card
Note: If both alarms (4) & (5) are enabled in the programming, the system will take the longer one for alarm time.
6) Door Propped-up Warning
a) The Door Propped-up Warning is enabled by programming from keypad at Programming Location 81
b) The warning starts at the expiry of the propped-up delay.
c) The warning beep is given by the internal buzzer only
4) Example 4 -- EM Card + Common User PIN :
i) Programming :
10
4
003
#
(a) (b) (c) (d) (e)
(a) The card is programmed for operating of the Output 1
(b) The operation is “EM Card + Common User PIN”
(c) Take ID number 003 in Group 1 to store the card, which is one of the IDs in 000-999
(d) Put the card close to the reader. One beep confirms the reading. (No need to key in a Common User PIN but
there MUST be a Common User PIN already recorded in Location 03; (or 04, 05 if for O/P 2, O/P 3).
(e) Press # to store the “Card” into memory. Two-beep confirms a valid entry
ii) Operation : (while the system is back to operation mode)
#
(a) (b) (c)
a) Put the EM card close to the reader. One-beep confirms the reading and 30 seconds waiting time is given for the
entry of the Common User PIN, the Amber LED keeps flashing
b) Key in the Common User PIN “1 3 5 7” (the number programmed in “Location 0 3” for Output 1 in the previous
Example)
c) Confirm it with the # key. Output 1 activates
5) Example 5 -- Delete an User PIN & / or EM Card (for O/P 1, 2 or 3) :
i) Delete An User PIN or A Lost EM Card
10
5 #
(a) (b) (c) (d)
a) Key in the User Group that the User ID belongs to. “10” for the Group 1, “20” for the Group 2, and “30” for the
Group 3
b) Key in “5” that is the Command Code for making a deletion here
c) Key in the User ID that stored the User PIN, the lost EM card or the EM Card+User PIN
d) Press the # key. Two-beep confirms a valid entry and the PIN and/or Card in that User ID is cleared
ii) Delete an EM Card
10
5 #
(a) (b) (c) (d)
a) Key in the User Group that the EM Card belongs to. “1 0” for the Group 1, “2 0” for the Group 2, and “3 0” for the
Group 3
b) Key in “5” that is the Command Code for making a deletion here
c) Put the EM card close to the reader. One-beep confirms the reading. Read the Card only also makes a valid
deletion to the Card working with the Common User PIN or the Secondary User PIN
d) Press the # key. Two-beep confirms a valid entry. The EM Card in that User ID is cleared. Key in the User ID is not required.
6) Example 6 – Clear The Whole Group of Users :
Whole group of users including the PINs and Cards can be cleared with the following command.
10
0999
#
(a) (b) (c)
a) The User Group 1 – “10” is selected to be cleared. “20” for Group 2 & “30” for Group 3
b) Key in the Group Deletion Command, 0 9 9 9
c) Confirm the deletion with #. All the User PINs and Cards in the Group 1 are cleared. It takes few seconds to a
minute to complete depending on the data stored.
7) Example 7 – Report A Duress While Using EM Card :
The Duress Codes are Prime User Codes in the system. In the “EM Card + Secondary User PIN” or “EM Card +
Common User PIN” operation, they can be used to replace the “Secondary User PIN” or the “Common User PIN”
to operate the specific output and report a duress alarm event. Programming is not required. The system has this
function automatically while Duress Code exists.
Read Card
User ID
Read Card
Common User PIN
Read Card
29