User's Manual
16
APPLICATION EXAMPLES
1) BASIC WIRINGS OF A SPLIT-DECODED DOOR LOCK
NOTE:
• Connect the 1N4004 as close as possible to the lock in parallel with the lock power terminals of the lock to absorb
the back EMF to prevent it from damaging the keypad. The 1N4004 is not required if the electric lock is AC operated.
• To avoid Electro-Static-Discharge from interfering with the operation of the keypad, always ground the (
-
) terminal
of the keypad to earth.
• Always connect DOOR SENSOR terminal to (
-
) ground if not used.
• Always connect TAMPER terminal to (
-
) ground if not used.
• Make 3-wire Connection (+,
-
, DATA I/O) to the keypad in the DK-2800 series. More than one keypads can be
connected in parallel.
-
ALARM O/P
-
KEY ACT O/P
-
N.O.
-
COM
-
N.C.
-
N.O.
-
COM
-
N.C.
-
N.O.
-
COM
-
N.C.
-
TAMPER
-
GND(
-
)
-
DOOR SENS
-
O/P 1 INHIB
-
INT. LOCK
-
DU OUT
-
DOOR BELL IN
-
EG IN
-
DATA I/O
-
KEYPAD PWR
-
GND(
-
)
-
12-24V DC
N.O.
ELECTRIC LOCK
1N4004
CATHODE
OUTPUT RELAY 1
N.O. Output for Fail-secure Lock
N.C. Output for Fail-safe Lock
N.C.
OUTPUT 1 OUTPUT 2 OUTPUT 3
DIGITAL KEYPAD
AD-1312 OR AP-960
EGRESS BUTTON
MORE EGRESS
BUTTON CAN
BE CONNECTED
IN PARALLEL
DOOR BELL
BUTTON
N.O.
(
-
)
(
-
)
(
-
)
N.O.
N.O.
RECORD-DELETE PINS OR CARDS FOR OUTPUT 1, 2, & 3 (Locations 10, 20 & 30)
Total of 1,200 User PINs and/or Cards are available for the 3 user groups to control the 3 outputs.
1) 1,000 ---- for Output 1 (Group 1)
2) 100 ------ for Output 2 (Group 2)
3) 100 ------ for Output 3 (Group 3)
The Private User PINs and Cards in the 3 user groups MUST be unique. Repeated PINs will be rejected. Secondary User
PINs in the “EM Card + Secondary User PIN” can be repeated. See the Important Note --- Programming Criteria for
Codes in page 14 for more information.
USER GROUP LOCATIONS
– Group 1 --For User PINs/Cards Controlling Output 1
1,000 Users are allowed in group 1 for O/P 1
– Group 2 --For User PINs/Cards Controlling Output 2
100 Users are allowed in group 2 for O/P 2
– Group 3 -- For User PINs/Cards Controlling Output 3
100 Users are allowed in group 3 for O/P 3
SELECTION OF OPERATION MEDIA
Number 1, 2, 3 or 4 represents the Media to be used to operate the keypad.
Number 5 is the authorization code for deleting of an PIN and/or Card from
its User ID.
= EM Card only; = Private User PIN only;
= EM Card + Secondary User PIN = EM Card + Common User PIN
= Delete an User PIN &/or Card from the selected User ID number
= Clear all the PINs & Cards from the selected Location. It takes
few seconds to a minute to complete depending on the Location
selected and the data stored.Please see the programming example
below for the details.
USER ID NUMBER
A 3-digit ID is an identified number for each User PIN and/or Card.
Repeated ID number will be rejected by the system
a) ID Number
000
-
999
for 1,000 User PINs/Cards to operate Output 1
b) ID Number
001
-
100
for 100 User PINs/Cards to operate Output 2
c) ID Number
001
-
100
for 100 User PINs/Cards to operate Output 3
CARD &/OR USER PINS
The User PINs can be 4-8 digits. Key in the User PIN on each ID Number box, then confirm it with # key
Just simply put the EM card close to the reader window to read it on each ID Number box, then, confirm it with
# key if it is a Card ONLY, or Card + Common User PIN entry. The Common User PIN is NOT required to key-in
here. It will go into its location automatically after the Card is read.
Read the Card first, then key in the Secondary User PIN on each ID Number box, then confirm it with # key if it
is Card + Secondary User PIN. The Secondary User PINs can be duplicated or a proprietary User PIN but can
not be a duplicate of a Prime Code. Owner can use the same secondary User PIN for a group of Cards as a group
Common User Code (or called Department Code) for a specific relay output.
Cards (Operation Media # 1, 3, & 4) and Private User PINs (Operation Media 2) MUST be unique. A repeated EM
card or Private User PIN will be rejected and one long beep will be generated by the system to notify the owner.
10
-
30
1
-
5 000
-
999 #
10
20
30
1 2
3 4
5
0999
CARD &/OR USER PIN VALIDATIONLOCATIONS MEDIA USER ID
CARD &/OR USER PIN
27