User's Manual
17
2) BASIC WIRINGS OF AN INTER-LOCK SYSTEM USING TWO SPLIT-DECODED KEYPADS
An inter-lock system needs two door controllers. This application example uses two keypad systems with simple cross
wire connection on their "Output 1 Inhibit" and "Inter-lock Control Output" terminals. It is necessary to link up the "(
-
)
GND" terminals of the two keypads as common ground to achieve the inter-lock logical functions.
• Use keypad to open the door from outside
• Press egress button to open the door from inside
• Connect the door magnetic sensors on the doors to monitor their positions
• While door 1 is open, then, door 2 is forced to keep close, or vice versa
• Use N.O. Relay output for fail-secure lock; and N.C. output for fail-safe lock
• Please also see the "NOTE" stated in the Application Example (1)
-
ALARM O/P
-
KEY ACT O/P
-
N.O.
-
COM
-
N.C.
-
N.O.
-
COM
-
N.C.
-
N.O.
-
COM
-
N.C.
-
TAMPER
-
GND(
-
)
-
DOOR SENS
-
O/P 1 INHIB
-
INT. LOCK
-
DU OUT
-
DOOR BELL IN
-
EG IN
-
DATA I/O
-
KEYPAD PWR
-
GND(
-
)
-
12-24V DC
N.O.
ELECTRIC LOCK
1N4004
DOOR 1
OUTPUT RELAY 1
N.O. Output for Fail-secure Lock
N.C. Output for Fail-safe Lock
N.C.
OUTPUT 1 OUTPUT 2 OUTPUT 3
DIGITAL KEYPAD
AD-1312 OR AP-960
EGRESS BUTTON
DOOR BELL
BUTTON
N.O.
(
-
)
(
-
)
N.O.
DOOR 1
SENSING
COMMON GROUND
(
-
)
DA-2800 OR DA-2801 DA-2800 OR DA-2801
CROSS WIRE CONNECTION FOR INTER-LOCK FUNCTIONS
-
ALARM O/P
-
KEY ACT O/P
-
N.O.
-
COM
-
N.C.
-
N.O.
-
COM
-
N.C.
-
N.O.
-
COM
-
N.C.
-
TAMPER
-
GND(
-
)
-
DOOR SENS
-
O/P 1 INHIB
-
INT. LOCK
-
DU OUT
-
DOOR BELL IN
-
EG IN
-
DATA I/O
-
KEYPAD PWR
-
GND(
-
)
-
12-24V DC
N.O.
ELECTRIC LOCK
1N4004
DOOR 2
OUTPUT RELAY 1
N.O. Output for Fail-secure Lock
N.C. Output for Fail-safe Lock
N.C.
OUTPUT 1 OUTPUT 2 OUTPUT 3
DIGITAL KEYPAD
AD-1312 OR AP-960
EGRESS BUTTON
DOOR BELL
BUTTON
N.O.
(
-
)
(
-
)
N.O.
DOOR 2
SENSING
OPERATION AND FUNCTIONS OF THE SUPER USER PIN
1) Operate Output 1, 2, and 3
The operation of the Super User PIN is just like a normal User PIN. Simply key-in the PIN with a specific output
number for the desired Output. The Super User PIN can also be used to reset an operating output timer instantly.
---------- Output 1 Activates or Output 1 Resets
---------- Output 2 Activates or Output 2 Resets
---------- Output 3 Activates or Output 3 Resets
2) Inhibit The User PINs For Output 1
The Super User PIN can also be used to inhibit the normal User PINs/Cards for the Output 1 (usually they are for
door strike). It enhances the security level of the access control system, such as to stop a keypad after office hour
or while the house is nobody inside. Once the Output 1 is inhibited, the User PINs/Cards for it become invalid and
those people even know the User PINs are refused during the system is inhibited. The inhibit function is toggled in
Start / Stop mode with the following code entry.
---------- The Whole Group of User PINs & Cards for Output 1 are Disabled
or Enabled in Toggle
NOTE:
The inhibit function setting with the Super User PIN applies to the whole group of User PINs and Cards for
Output 1 ONLY, but not for Output 2 or Output 3.
For safety reason, the inhibit function initiated with the Super User PIN does not govern the Egress Button. The
door still can be opened with it from inside.
The Super User PINs are always valid. They are not governed by any inhibit or lock out function in the system.
RECORD THE COMMON USER PINS FOR OUTPUT 1, 2 & 3 (Locations 03, 04, & 05)
The Common User PINs 1, 2 and 3 are prepared for operating of the Output 1, Output 2 and Output 3 respectively as
an enhance code. The Common User PINs MUST work in the form of “Card + Common PIN” to operate the outputs to
increase the security of the access control system. See Locations 10, 20 & 30 for more information.
NOTE : Common User PIN alone can NOT be used to operate the Outputs directly.
COMMON USER PIN LOCATIONS
-- Location Stores The Common User PIN for Output 1
-- Location Stores The Common User PIN for Output 2
-- Location Stores The Common User PIN for Output 3
COMMON USER PINS
The Common User PIN can be 4 to 8 digits. Press # key to confirm the code entry.
When a new Common User PIN is keyed in and confirmed, the old one is replaced.
Example: Set a Common User PIN with the number of “1 3 5 7” for Output 1 ----
To deleted a Common User PIN from memory: Key in just the Location number and #. ----
4 to 8 Digits
SUPER USER PIN
SUPER USER PIN
SUPER USER PIN
SUPER USER PIN
COMMON USER PIN VALIDATIONLOCATIONS
#
1
#
2
#
3
#
9
03
1357
#
03
#
03
04
05
#
03
-
05
26
INDIVIDUAL