APPLICATION HINTS FOR THE AUXILIARY TERMINALS
The tamper switch is Normally Closed while the keypad
is secured on the gang box. It is open when the keypad
is removed from the gang box. To get warning at
sabotage, connect the tamper switch to the TAMPER
terminal of the DA-2800. If more than one tamper
switches are connected, just connect them in series.
With the help of a Normally Closed door
position sensor (usually a magnetic door
switch) on the door to set up the following
functions:
Door Auto Relock -- The system will immediately
relock the door after a valid access has been gained to
prevent "tailgate" entries.
Door Forced-open Alarm -- The keypad will generate
alarm instantly if the door is forced to open. Enable the
function at Location 80.
Door Propped-up Alarm -- The keypad will generate
alarm if the door is left open longer than the pre-set
delay time. Enable the function at Location 81.
Inter-lock Control -- When the door is open, the
interlock output of the keypad will give a (
-
) command
to stop the other keypad in an inter-lock system.
Door Opening Alarm -- Door Opening Alarm is
designed for the emergency door only. It is always
given when the door is opened unless a valid user code
or card is used prior to the door is opened. Enable the
function at Location 91.
a)
b)
c)
d)
e)
(A) TAMPER N.C.
(B) DOOR SENS
The Alarm Output switches to (
-
) ground in door forced to open or the door open after Egress Delay. You may
use it to turn ON an LED lamp and/ or a small buzzer to notify a guard; or connect it to a 24 hour Normally
Open protection zone of an alarm system. See Location 80 and Location 91 for more information about these
functions.
Only one connection option is recommended. Make sure that the sink current does not exceed the maximum
rating of 100mA.
(C) ALARM OUTPUT
GND(
-
)
N.C
TAMPER SWITCH
OF THE KEYPAD
GND(
-
)
DOOR
SENS
18
ALARM
O/P
KEY ACT
O/P
GND
(
-
)
ALARM
O/P
KEY ACT
O/P
GND
(
-
)
Example:
User Name Location Function Code User ID PIN/Code Card # Remark
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
--
1,000
RECORD A MASTER CODE --For Both Master & Slave Keypads (Location 01)
MASTER CODE
Master Code is the authorization code for setting the system to programming mode. It is NOT an User Code
operating of the output relays.
The Master Code can be 4 to 8 digits. Press # key to confirm code entry
When a new master code is keyed in and confirmed, the old master code is replaced automatically.
The master code is also the Link-up Code between the keypad and the controller of the system in Split-decoded
operation. Master and Slave Keypads are required to set with the same Master Code.
Example: Set a Master Code with the number of “2 2 3 3” ----
RECORD A SUPER USER PIN (Location 02)
The Super User PIN has TWO functions. It is prepared for the owner to simply use only one User PIN to operate the
three outputs of the keypad and make operation inhibit enable / disable to the system outputs.
SUPER USER PIN
The Super User PIN can be 4 to 8 digits.
Two beeps will be heard after pressing the # key to confirm code entry.
When a new Super User PIN is keyed in and confirmed, the old one is replaced.
Example: Set a Super User PIN with the number of “2 5 8 0” ----
To deleted a Super User PIN from memory: Key in just the Location number and #. ----
4 to 8 Digits
SUPER USER PIN VALIDATIONLOCATION
02
02
2580
#
02
#
#
4 to 8 Digits